An adaptive socket with auto-adjusting air bladders for interfacing transhumeral prosthesis: A pilot study

Author:

Gu Yikun1ORCID,Yang Dapeng1,Osborn Luke2ORCID,Candrea Daniel3,Liu Hong1,Thakor Nitish2

Affiliation:

1. State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China

2. Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA

3. Biomedical Engineering, Duke University, Durham, NC, USA

Abstract

Comfort is a critical aspect in the application of wearable device, such as rehabilitation robots and upper limb prostheses. As a physical interface between human body and prosthetic limb, the socket and its comfort largely contribute to the user’s acceptance. Traditional sockets are static, lacking dynamic adjustment mechanism for the contact pressure. To ensure a reliable suspension during daily activities, the socket is usually designed to be tightly attached, with a large stress, on the residual limb, which may introduce considerable discomfort during long-term use. In this article, we present a novel adaptive transhumeral socket, in which we employ four independent bladders contacting with the stump. Not only can these bladders provide a necessary suspension for the device but also form an air cushion (soft body) that helps relieve the pressure concentration between the biological body and physical prosthesis. In real time, this adaptive socket continuously monitors the limb posture, the operating load, and the contacting pressure between the socket and the limb, and then dynamically adjusts the clamping force to ensure a reliable attachment during various daily activities. Since well adapting to the contours of the stump, the bladders can effectively accommodate the volume change of the stump, making a balanced load distribution on load-tolerant areas. Through modeling and numerical analysis, we established a dynamic strategy for estimating the external load and an automatic scheme for adjusting the bladders’ air pressure. Finally, a close-loop control was constructed based on the contact pressure measured by our self-developed force sensors. Our preliminary experiments on one normal (i.e. non-amputee) subject verified the effectiveness of the proposed method, showing that the adaptive socket can considerably reduce the socket–limb contact pressure while sustaining a secure suspension on the upper arm.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3