Endosonographic evaluation of the mediastinum through the i-gel O2 supraglottic airway device

Author:

Piccioni Federico1ORCID,Codazzi Daniela1,Paleari Maria C.2,Previtali Paola1,Delconte Gabriele3,Fumagalli Luca1,Manzi Renato1,Faustini Marco1,Persiani Laura1,Rizzi Maurilia1,Sodi Federico2ORCID,Masci Enzo3

Affiliation:

1. Department of Critical and Supportive Therapy, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy

2. School of Anesthesia and Intensive Care, University of Milan, Milan, Italy

3. Diagnostic and Therapeutic Endoscopic Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy

Abstract

Introduction: Endobronchial ultrasound (EBUS) is an endoscopic diagnostic procedure combining flexible fibrobronchoscopy with ultrasound techniques; it allows transbronchial needle aspiration biopsy for the diagnosis and staging of mediastinal masses. We present our preliminary experience with the use of the i-gel O2 supraglottic airway device for management of EBUS procedures. Methods: An observational study on 39 patients who underwent EBUS under general anesthesia was performed. Airways were managed with i-gel O2 by anesthesiologists unfamiliar with it. Data collected included patient characteristics, i-gel O2 positioning, mechanical ventilation, procedure, and complications occurring during and after the EBUS. Results: The i-gel airway was successfully positioned during the first attempt in 34/39 cases (87.2%). No failed positioning was recorded. The EBUS scope easily passed through the i-gel in all patients and in 14 (35.6%) cases it was also inserted through the esophagus allowing the examination or fine needle aspiration of paraesophageal lymph nodes. In one case, during the EBUS procedure, the i-gel was dislocated but easily put in place again. During EBUS, air leakages were significant in 2 cases (5.1%) and minimal in 14 cases (35.9%). A brief self-solved laryngospasm and a bronchospasm during bronchoscopy were recorded. After recovery, no patients had dysphagia; mild odynophagia and pharyngodinia were referred by 2 (5.1%) and 12 (30.1%) patients, respectively. Conclusions: The i-gel O2 airway is easy to position and manage even for anesthesiologists unfamiliar with it. This supraglottic airway device is suitable for a complete endosonographic evaluation of the mediastinum.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine