Quality Assurance of a Record-and-Verify System

Author:

Baiotto Barbara1,Bracco Christian1,Bresciani Sara1,Mastantuoni Antonella1,Gabriele Pietro2,Stasi Michele1

Affiliation:

1. Medical Physics Department, Institute for Cancer Treatment and Research, Candiolo (Turin), Italy

2. Radiotherapy Department, Institute for Cancer Treatment and Research, Candiolo (Turin), Italy

Abstract

Aims and background With the introduction of more complex three-dimensional conformal radiotherapy and intensity-modulated radiotherapy techniques in clinical practice, the use of record-and-verify systems is recommended to improve the accuracy of radiotherapy treatments. The aim of the present study was to evaluate, for a commercial record-and-verify system, the efficiency, integration with the treatment planning system, and impact of manual checking of data. The most frequent errors or misses were also evaluated. Materials and methods The development of internal protocols to systematically implement new technologies has been identified as a priority in the departmental quality assurance process. Data electronically fed into the record-and-verify system were compared with those manually recorded in the clinical paper chart over a period of almost 6 years (October 2000 to December 2006). A total of 7768 treated patients was reviewed. The check was performed by using a homemade data base in which the errors are stratified as follows: 1) general section, 2) geometric and dosimetric section, and 3) delivered dose section. Results On a total of 7768 checked patients, one or more mismatches between treatment planning system data and record-and-verify system data or paper chart data were observed for 452 patients (5.8% of total number of inspected patients). The percentage of discrepancies out of the total was: 2.2% in the general section, 3.3% in the dosimetric and geometric section, and 4.2% in the delivered-dose section. Conclusions Although record-and-verify systems assume a crucial role in the accuracy and reproducibility of radiation treatment, their inability to eradicate all the errors requires vigilance on the part of the radiation therapy and physics team.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3