Affiliation:
1. General Electric Company Corporate Research and Development
Schenectady, NY 12305
Abstract
This paper deals with the thermal characterization of fiberglass insu lation used in baking oven applications. The apparent thermal conductivities of fiber glass bats were measured with a commercially available guarded hot plate k-tester as a function of density, thickness, hot and cold surface emissivities and mean tempera ture levels applicable to range operation and self cleaning conditions. An axisym metnc conduction analysis was performed to estimate the k-tester accuracy, and a few calibration measurements were executed with a fiberglass mat provided by the k-tester manufacturer. The apparent thermal conductivities, measured within the specific ranges of the parameters listed above, were correlated with a model which in cludes the gas and solid conduction, as well as radiation transport.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Heat Transfer Across Opaque Fibers;Journal of Heat Transfer;2012-05-22