Exploring correlations between anatomic characteristics of dialysis arteriovenous fistula stenosis and arteriovenous fistula blood flow rate (Qa)

Author:

Nassar George M1,Beathard Gerald2

Affiliation:

1. Dialysis Access Management Centers, Nephrology Dialysis and Transplantation Associates, The Kidney Institute & Houston Methodist Hospital, Weill Cornell University, Houston, TX, USA

2. University of Texas Medical Branch, Galveston, TX, USA

Abstract

Background: Radiologic justification for endovascular treatment of a dialysis arteriovenous fistula circuit stenosis is currently based on ⩾50% severity. However, the clinical significance of any given stenosis is not always clear. The minimum luminal diameter of any stenotic lesion in the arteriovenous fistula circuit might exert a more predictive effect on the arteriovenous fistula blood flow rate (Qa). Methods: To investigate relationships between anatomic parameters of stenosis and Qa, this study was conducted in a cohort of patients with a variety of arteriovenous fistula stenotic lesions. The goals were to determine (1) the degree of correlation between arteriovenous fistula stenosis estimated during the procedure, and that which is measured, and (2) the correlations between two anatomic stenosis parameters (percent stenosis and stenosis minimum luminal diameter) and Qa. Results: The cohort comprised 113 patients. Only a moderate correlation between estimated and measured stenosis was seen. A correlation between measured stenosis and Qa for the whole cohort was not seen, but a weak correlation between estimated stenosis and Qa was seen. Correlations between stenosis minimum luminal diameter and Qa were superior. The superiority of stenosis minimum luminal diameter to percent stenosis in correlating with a Qa of <500 mL/h was also demonstrated by receiver operating characteristics curve analysis. Stenosis minimum luminal diameter cutoffs of ⩽2.5 mm or >4 mm seemed to have a good predictive value of Qa. Conclusions: Percent stenosis determination is fraught with uncertainty and exhibits a weak correlation with Qa. Compared with percent stenosis, the minimum luminal diameter of the stenosis demonstrates a superior correlation with Qa.

Funder

Renal Research, Inc.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3