Hemodialysis access flow measurement: Comparison of ultrasound dilution and ultrafiltration method on NIKKISO DBB-EXA™ dialysis machine

Author:

Kosmadakis Georgios1ORCID,Enache Ioana1,Gueret Claudine1,Haskour Abraham1,Necoara Aura1,Deville Clémence1,Baudenon Julien1,Rance Nicole1

Affiliation:

1. AURA Santé, Clermont-Ferrand, France

Abstract

Background: The methods of estimating vascular access (VA) flow rates are usually based on the indicator dilution theory by measuring recirculation during dialysis sessions. Methods: This is an observational study comparing the VA flow rates measured by NIKKISO DBB-EXA™ and Transonic®. Sixty-five patients (38 M/27 F, mean age 72 ± 10 years) participated in the study. We measured the VA flow rates during dialysis twice with each method and repeated the procedure 7 days later. Results: In 130 double measurements for each method on the same day, mean flow with Transonic® was 1413±715 ml/min and with DBB-EXA™ 1297 ± 664 ml/min. In Bland-Altman analysis, the mean difference between the two methods was 159 ± 211 ml/min (limits of agreement: −274 and 572 ml/min). Eighty-one out of the 130 DBB-EXA™ measurements were within 25% of the Transonic® measurements (62% accuracy). Regarding reproducibility of each method on different days, mean difference in the Bland-Altman analysis was 29 ± 620 ml/min (limits of agreement: −1186 and 1244 ml/min) for the Transonic® measurements and 132 ± 625 ml/min (limits of agreement: −1092 and 1356 ml/min) for the DBB-EXA™ measurements. The measurements on two different days were within 25% of each other for 52 of the 65 patients (80%) with the Transonic® method, and for 35 of the 65 patients (54%) with the DBB-EXA™ method. Conclusions: In conclusion, the DBB-EXA™ method underestimates VA flow rates compared to the Transonic® technique, resulting in a limited accuracy of 62%. There was poor reproducibility for both methods in different day measurements with better performance of the Transonic® technique. The DBB-EXA™ method could be used as a simple tool for a rough estimate of VA flow rates but cannot replace the Transonic® reference method.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3