Effect of catheter diameter on left innominate vein in breast cancer patients after totally implantable venous access port placement

Author:

Song Myung Gyu1,Seo Tae-Seok1,Kim Yun Hwan2,Cho Sung Bum2,Chung Hwan Hoon3,Lee Seung Hwa3,Jung Euichul4

Affiliation:

1. Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea

2. Department of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea

3. Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Seoul, Korea

4. Department of Radiology, Nowon Eulji Medical Center, Eulji University College of Medicine, Seoul, Korea

Abstract

The effect of catheter diameter on left innominate vein stenosis in breast cancer patients after totally implantable venous access port placement. Purpose: To evaluate the effect of catheter diameter on left innominate vein stenosis in breast cancer patients after placement of totally implantable venous access ports. Materials and methods: Totally implantable venous access ports were placed via the left internal jugular vein in 241 women with right breast cancer from January 2010 to December 2014 (mean age, 51.5 years; range, 19–83 years). There were 67 totally implantable venous access ports with a 6.5F catheter and 142 totally implantable venous access ports with an 8F catheter. Medical records were retrospectively reviewed. The presence of significant left innominate vein stenosis and tip location of the catheter was evaluated on chest computed tomography images. Statistical analysis was performed. Results: Left innominate vein stenosis developed in 1 (1.5%) and 13 (9.2%) patients after implantation with 6.5 and 8F catheters, respectively. Difference in the cumulative incidence of left innominate vein stenosis was statistically significant between the two groups (log rank test p-value: 0.002). In Cox regression analysis, the hazard ratio for left innominate vein stenosis was 20.766 ( p = 0.005) for an 8F catheter. Conclusion: The incidence of left innominate vein stenosis was higher after implantation of totally implantable venous access ports with 8F catheter rather than with 6.5F catheter. Considering that using 8F catheter versus 6.5F catheter has no advantage in terms of performance of the device, the results of our study suggest that ports with catheters >7F should be avoided.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3