Comparison of peripheral cutting balloon angioplasty with conventional balloon angioplasty for recurrent hemodialysis vascular access stenosis: A prospective randomized controlled trial

Author:

Murakami Masaaki1ORCID,Furushima Daisuke2,Hamamoto Shingo3,Yamada Hiroshi3,Okawa Takao1,Tanaka Satoshi1,Nagai Kojiro1

Affiliation:

1. Department of Nephrology, Shizuoka General Hospital, Shizuoka, Japan

2. School of Health Science, Faculty of Medicine, Kagoshima University, Kagoshima, Japan

3. Department of Drug Evaluation and Informatics, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, Japan

Abstract

Purpose: This study aimed to compare the efficacy and safety of cutting balloon angioplasty (CBA) and conventional balloon angioplasty (control group) for recurrent vascular access stenosis in arteriovenous fistulas. Materials and methods: This prospective, randomized single-center clinical trial included patients with hemodynamically significant recurrent vascular access stenosis of an arteriovenous fistula. The Kaplan–Meier method was used to assess primary patency, whereas the log-rank test was used to evaluate differences in patency between groups. Functional evaluations were performed using Doppler ultrasonography. Results: Patients ( n = 122) were randomly assigned to undergo CBA or conventional balloon angioplasty between December 2012 and November 2017. The clinical success rate was 100% in both groups. The anatomical success rates were 65% and 56% in the CBA and control groups, respectively. The primary patency of the target lesion was significantly better in the CBA group (33.3%) than in the control group (16.1%) at 6 months (hazard ratio, 0.50; 95% confidence interval, 0.33–0.77; p = 0.00171). The stenosis percentage decreased significantly after angioplasty in the CBA group (Δ-50.7%) compared with the control group (Δ-41.9%) ( p = 0.0008). Access flow, measured using duplex Doppler ultrasonography, improved after angioplasty in both groups (300–526 ml/min in the control group and, 268–546 ml/min in the CBA group). Change in access flow (Δ + 278 ± 162) in the CBA group tended to be greater than that in the control group (Δ + 226 ± 151) ( p = 0.07). However, the difference was not statistically significant. Conclusion: In patients with recurrent vascular access stenosis of the arteriovenous fistula CBA is effective and superior to conventional angioplasty.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3