Use of a novel tapered, scoring balloon to treat juxta-anastomotic stenosis in AV fistula

Author:

Li Xiangjie1ORCID,Wang Zhe1ORCID,Zhao Xia1,Sun Hao1,Fu Qining1ORCID

Affiliation:

1. Department of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China

Abstract

Background: Juxta-anastomotic stenosis, the most common lesion in arteriovenous fistula, creates a dilemma for optimal balloon size choosing during PTA. Objectives: To descript the effect of a novel tapered scoring balloon catheter (DK Medtech, Suzhou, China) which has a conical shape with an increasing diameter from the front part of the balloon to the end, and three non-slip elements attached on the surface of the balloon. Research design: Case series of 10 patients used this balloon catheter was retrospectively analyzed. Subjects: Patients with juxta-anastomotic stenosis. Measures: A retrospective review of 10 cases using the novel tapered, scoring balloon catheter in our center was performed. Results: All cases were clinical technique success. The average total procedure time was 16.7 min with 2:14 of fluoroscopy time. No complications such as vascular rupture or dissection occurred. The primary patency rates at 6 and 12 month were 80% and 50% separately. Conclusions: This tapered scoring balloon provides an economical, safe, and efficient management for juxta-anastomotic stenosis.

Funder

Chongqing Science and Technology Bureau and Health Commission joint medical research project

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3