Pain upon inserting a peripheral intravenous catheter: Size does not matter

Author:

van Loon Fredericus HJ123,Puijn Lisette APM3,van Aarle Wesly H3,Dierick-van Daele Angelique TM12,Bouwman Arthur RA34

Affiliation:

1. Department of Research and Education, Catharina Hospital, Eindhoven, The Netherlands

2. Fontys University of Applied Sciences, Eindhoven, The Netherlands

3. Department of Anesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, Eindhoven, The Netherlands

4. Department of Signal Processing Systems and Electrical Engineering, Eindhoven University of Technology (TU/e), Eindhoven, The Netherlands

Abstract

Background: Approximately 1.2 billion peripheral intravenous catheters are inserted across the world annually. It is known that intravenous cannulation may be a painful procedure, which affects cognitive abilities by increasing anxiety and discomfort. Aim: We hypothesized that inserting a smaller sized peripheral intravenous catheter has a lower level of pain sensation compared to a larger sized catheter. Methods: This observational, cross-sectional study was conducted between May and October 2016, in which surgical patients, aged 18 years or older, were eligible to participate. Experienced anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access according to the standards of care. The primary outcome was pain (verbal numeric rating scale, 0–10) upon intravenous cannulation. Results: A total of 1063 patients were included and they were divided into four groups: group 1, 22 gauge (N = 29); group 2, 20 gauge (N = 447); group 3, 18 gauge (N = 531); and group 4, sized over 18 gauge (N = 56). Inserting an 18-gauged peripheral intravenous catheter resulted in the lowest pain score (3.2 ± 2.0). As a result of the multivariate linear analysis, five factors were significantly associated with pain upon inserting a peripheral intravenous catheter (sex, American Society of Anesthesiology classification, a patients risk profile on the A-DIVA scale, site of cannulation on the extremity, and whether or not the attempt was successful); however, the size of the inserted peripheral intravenous catheter had no significant relation to the primary outcome. Conclusion: Inserting a smaller sized peripheral intravenous catheter did not result in a lower pain sensation. Moreover, to prevent pain upon inserting a peripheral intravenous catheter, an unsuccessful attempt must be avoided.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3