Risk factors for in-stent restenosis in maintenance hemodialysis patients with central venous occlusive disease and biomechanical assessment of stents

Author:

Yu Yang12,Xiong Yuqin3,Li Tao4,Zhou Jingyuan5,Yan Weijie6,Xiong Yan4,Chen Yu5,Fu Ping1ORCID

Affiliation:

1. Kidney Research Laboratory, Division of Nephrology, West China Hospital of Sichuan University, Chengdu, China

2. Interventional Therapy Center, West China Hospital of Sichuan University, Chengdu, China

3. West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China

4. College of Mechanical Engineering, Sichuan University, Chengdu, China

5. Department of Applied Mechanics, Sichuan University, Chengdu, China

6. Division of Radiology, West China Hospital of Sichuan University, Chengdu, China

Abstract

Objectives: To investigate the risk factors and biomechanical mechanisms of in-stent restenosis (ISR) in central venous occlusive disease (CVOD). Patients and methods: This retrospective study consecutively included 77 maintenance hemodialysis (MHD) patients with CVOD who received the first percutaneous transluminal angioplasty with stenting (PTS) due to symptomatic CVOD in a tertiary hospital. The mean age was 59.7 ± 14.0 years, and 51.9% of patients were male. The clinical characteristics, occurrence of ISR and patency rates were recorded. Finite element method was applied to assess the biomechanical properties of stents. Results: Among 77 patients with a mean CVS score of 8.0 ± 2.8, 20.8%, 62.3%, and 16.9% of patients had the main vein of CVOD in the subclavian vein, brachiocephalic vein, and superior vena cava, respectively. A total of 72 (93.5%) patients received successful PTS treatment, for which the stents implanted were mainly Fluency covered stent (48.6%) and SMART bare stent (31.9%). During 15 (10–24)-months of follow-up, ISR occurred in 36.1% of the 72 patients. The primary and assisted primary patency rates at 6, 12, and 18 months were 78%, 56%, 42% and 95%, 90%, 87%, respectively. A prolonged dialysis vintage was an independent risk factor for ISR, yet the stent type or the main vein location was not correlated with ISR. Among three laser-engraving stents, the SMART stent was the best in terms of flexibility, stress, and strain on stents but worst in stress or strain on vessels. The Luminexx stent was the best in radial force and worst in stress or strain on stents. The Vici stent was the best in stress and strain on vessels and worst in radial force and flexibility. Conclusions: An unsatisfactory comprehensive biomechanical performance from configurations rooted in existing stents may account for the high incidence of ISR in CVOD.

Funder

Key Project of Research and Development of Science and Technology Department of Sichuan Province

1.3.5 project for disciplines of excellence, West China Hospital, Sichuan University

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Reduced-Dimension Polarization-Space-Time Adaptive Processing Method for Airborne Conformal Array Radar;IGARSS 2023 - 2023 IEEE International Geoscience and Remote Sensing Symposium;2023-07-16

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3