Mechanical thrombectomy with the InThrill device for thrombosed hemodialysis access: A single center experience

Author:

Katsiroubas Jessica1,Chitanvis Maneesha1,Waldman Rachel1,Malik Rajesh2,Ilonzo Nicole2ORCID

Affiliation:

1. Department of Surgery, New York Presbyterian Brooklyn Methodist Hospital, Brooklyn, NY, USA

2. Department of Surgery, Weill Cornell Medicine, Brooklyn, NY, USA

Abstract

Objective: To assess the effectiveness and safety of the InThrill Thrombectomy System in treating thrombosed arteriovenous fistulas (AVFs) and grafts (AVGs) via mechanical thrombectomy. Methods: Institutional database was retrospectively searched to identify all thrombectomy procedures performed using the study device at our hospital for thrombosis of AVFs or AVGs. Inclusion criteria encompassed patients aged 18 and above who underwent AV access thrombectomy using the study device. Intraprocedural metrics, including procedure time, device time, blood loss, and adjunctive procedures were collected. Technical success was defined as restoration of flow combined with <30% residual diameter stenosis of the treated vascular segment. Clinical success was defined as the resumption of normal hemodialysis for a minimum of at least one session following intervention. Through 3-month follow-up, patency, and adverse events were evaluated. Results: A total of 20 thrombectomies were performed on 2 AVFs and 18 AVGs in 13 patients. Median procedure and device times were 45 and 10 min, respectively. Balloon angioplasty was performed in all cases with additional stenting in 40% (8/20) of cases to address stenosis following thrombus removal. No other mechanical thrombectomy devices were utilized. Intraprocedural thrombolytics were not administered in any case. Average blood loss was 10 mL. The technical success and clinical success rates were 100% (20/20) and 95% (19/20), respectively. There were no intraoperative adverse events. One patient developed a post-operative minor hematoma, and one patient developed a post-operative pseudoaneurysm at the access site. The primary patency rate was 77% (10/13) at 1 month. Both assisted primary and secondary patency rates were 100% at 1 and 3 months. Conclusion: These preliminary results suggest that the InThrill Thrombectomy System is rapid, safe, and effective for thrombolytic-free treatment of AV access thrombosis in hemodialysis patients.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3