Appropriate Resource Utilization in Portable Noninvasive Vascular Studies: The Role of Disruptive Technology

Author:

Patel Darshan1,Satiani Bhagwan1,Mong Renee1,Baetz Laureen1,Spiezio Kim1

Affiliation:

1. Peripheral Vascular Laboratory (Ross Heart Hospital) & Division of Vascular Surgery, Department of Surgery, The Ohio State University College of Medicine & Public Health, Columbus, Ohio.

Abstract

Purpose Common reasons for avoiding portable noninvasive vascular laboratory (VL) studies include degraded study quality, repetitive stress injuries, the wear and tear of equipment, and inefficiency. We examined the efficiency of portable VL studies in the context of productivity and potential loss of revenue. Methods From January 2005 to March 2005, sonographers in the VL recorded the time required to conduct “in-lab” and portable studies with conventional full-size scanners. A blended average based on frequency of portable studies within different areas of the hospital was used to determine the additional time required to conduct a portable study. The sonographer also made a qualitative assessment on the necessity of the portable study in each case. Results The VL performed an average of 31 portable studies (18% of total studies) per week. On average, portable testing increased overall study time by 17.7 min per test and 1.8 h per day, resulting in 9.1 h of additional study time lost per week. The potential increase in study volume could result in incremental annual gross revenue of $41,204 to $77,258 for the VL. The sonographers estimated that 24% to 45% of portable procedures could have been conducted in the lab. Conclusions In addition to suboptimal imaging and sonographer/equipment wear and tear, the current practice of unrestricted portable tests performed with existing bulky equipment is economically inefficient. New “disruptive” technology, leading to high-quality bedside scanning and limiting portable studies to patients who genuinely need it, will allow for greater productivity, decrease wait time for elective outpatients, and generate incremental revenue for the VL.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3