Abstract

Objective. Preoperative imaging in primary hyperparathyroidism (PHPT) is essential for planning of parathyroidectomy—particularly for selection of a minimally invasive approach. The objective of this cohort study was to evaluate the diagnostic precision of 3D virtual neck exploration (3D-VNE), to evaluate its impact on choice of surgical approach, and to document the correlation with long-term outcomes. Methods. 235 consecutive patients with PHPT were studied (January 2014 to December 2018), with 6-month follow-up. 220 patients had a preoperative computed tomography (CT), 172 of these had a 3D-VNE based on the CT, and 226 patients had a Tc-99m sestamibi scan. Results. Sensitivity of exact, per gland, adenoma localization was 57.09% (95% CI: 50.85–63.10%) for nonspecialized radiologist interpretation of CT scan, 58.17% (95% CI: 51.99–64.10%) for Tc-99m sestamibi scan, and 90.21% (95% CI: 85.21–93.64%) for 3D-VNE, and thereby favoring 3D-VNE compared to CT scan alone (OR 34.5, 95% CI: 9.19–290.56%, P < 2.2 × 10−16) and to Tc-99m sestamibi scan (OR 16.25, 95% CI: 6.05–61.42%, P = 3.1 × 10−15). Specificity was 87.38% for CT scan, 86.36% for 3D-VNE, and 90% for Tc-99m sestamibi scan ( P > .05). The cure rate was 100%. The long-term recurrence rate (RR) was 2.978%. The RR was 1.324% in the video-assisted parathyroidectomy group of 151 patients and 5.952% in the group of 84 patients with cervicotomy ( P = .0459). Conclusion. CT-based 3D-VNE proved to be the most accurate localizing study in PHPT and aided in selecting patients for targeted minimally invasive parathyroidectomy, which was associated with the lower recurrence rate. 3D-VNE could be proposed as a first-line imaging study in patients with PHPT.

Publisher

SAGE Publications

Subject

Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3