How Much Stereoscopic Effect Does Laparoscopy Need? Controlled, Prospective Randomized Trial on Surgical Task Efficiency in Standardized Phantom Tasks

Author:

Kunert Wolfgang1ORCID,Auer Thomas1,Storz Pirmin1,Braun Manuel1,Kirschniak Andreas1ORCID,Falch Claudius1

Affiliation:

1. University Hospital Tuebingen, Germany

Abstract

Background. To regain 2-eyed vision in laparoscopy, dual-channeled optics have been introduced. With this optics design, the distance between the 2 front lenses defines how much stereoscopic effect is seen. This study quantifies the impact of an enhanced and a reduced stereo effect on surgical task efficiency. Methods. A prospective single-blinded study was performed with 20 laparoscopic novices in an inanimate experimental setting. A standard bichannelled stereo system was used to perform a suturing and knotting task. The working distance and the task size were scaled to vary the stereo effect and, thereby, simulate hypothetic stereo optics with enhanced and reduced optical bases. The task performances were timed, and the number of trials for stitching out was counted. The participants finally filled out a questionnaire to collect subjective impressions. Results. The increase of the stereo effect by 50% caused no objective improvement in laparoscopic knotting compared with typical 3D (control group with stereo basis of 4.5 mm). But ergonomic disadvantages (headache) were subjectively reported in 1 of 20 cases in the questionnaire. The reduction of the stereo effect by one-third led to a significantly longer average execution time. There was no significant dependence found between stereo effect and number of stich-out trials, stitching precision, or knotting quality. Conclusions. Considering laparoscopy, it does not seem advisable to enhance the stereo effect because of ergonomic problems. Otherwise, a miniaturization of the 3D scope (5 mm version) is problematic because its benefit mostly shrinks with the reduced stereo effect.

Publisher

SAGE Publications

Subject

Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3