A systematic review and meta-analysis on the efficacy and safety of the Baska mask versus other laryngeal mask airways during general anaesthesia

Author:

Fadlalmola Hammad Ali1ORCID,Elhusein Amal Mohamed2,Osman Abdalla Mohamed3,Balola Hamza Hosean4,Ebrahim Elturabi Elsayed5,Babiker Sitelgeel Hamouda6,Ghoneim Nagwa Ibrahim7,Ebrahim Raga Abdelfatah8,Ali Maha Abdalla9,Mohammed Amani Abdelgader10ORCID,Eshag Ghada Siddig8,Mohamed Sara Elsadig11ORCID,Shaaeldein Farida Rahamtalla11,Al-Sayaghi Khaled Mohammed12

Affiliation:

1. Department of Community Health Nursing, College of Nursing, Taibah University, Al-Madinah, Saudi Arabia

2. Nursing Department, College of Applied Medical Science, University of Bisha, Bisha, Saudi Arabia

3. Department of Community and Mental Health, College of Nursing, Najran University, Najran, Saudi Arabia

4. Department of Community Health Nursing, Batterjee Medical College for Sciences and Technology, Khamis Mushait, Saudi Arabia

5. Department of Medical Surgical Nursing, Nursing Science Department, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia

6. College of Applied Medical Sciences, University of Hafr Al Batin, Hafr Al Batin, Saudi Arabia

7. Critical Care and Emergency Nursing, Faculty of Nursing, Tanta University, Tanta, Egypt

8. Cardiothoracic Nursing, College of Nursing, Jazan University, Jazan, Saudi Arabia

9. Pediatric Nursing, College of Nursing, Jazan University, Jazan, Saudi Arabia

10. Obstetrics and Gynecological Nursing, College of Nursing, Jazan University, Jazan, Saudi Arabia

11. Community Health Nursing, College of Nursing, Jazan University, Jazan, Saudi Arabia

12. Department of Medical Surgical Nursing, College of Nursing, Taibah University, Al-Madinah, Saudi Arabia

Abstract

Background: The Baska mask is a supraglottic airway device used during general anaesthesia that combines features from various other devices. This systematic review aims to compare its efficacy and safety with other laryngeal mask airways. Methods: Randomised controlled trials were identified by searching PubMed, Scopus, Web of Science and Cochrane Library. RevMan software was used for meta-analysis, with mean difference and risk ratios calculated for continuous and dichotomous data, respectively, along with a 95% confidence interval. Results: The meta-analysis found that the Baska mask provides a better oropharyngeal seal pressure (mean difference = 7.03; 95% confidence interval = [6.00, 8.07], p < 0.00001) and a higher rate of maximal seal pressure (risk ratio = 18.38; 95% confidence interval = [2.53, 133.47], p = 0.004) compared to other laryngeal mask airways. However, the Baska mask had lower success rates in first-attempt insertion (risk ratio = 0.79; 95% confidence interval = [0.72, 0.86], p < 0.00001) and higher rates of insertion manipulation (risk ratio = 16.64; 95% confidence interval = [5.86, 47.24], p < 0.00001). Conclusion: The Baska mask offers better oropharyngeal seal pressure, but may be more difficult to insert than other laryngeal mask airways, without causing significant delays. The Baska mask appears as safe as other laryngeal mask airways, but larger trials are needed to support these findings.

Publisher

SAGE Publications

Subject

Medical–Surgical Nursing,Anesthesiology and Pain Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3