Digital Analysis of the Dimensional Change Of an Irreversible Hydrocolloid Impression Material (Alginate) with Varying Storage Times

Author:

Ibrahem Fatemah1,Giugliano Thomas1,Ruff Ryan Richard2,Choi Mijin1

Affiliation:

1. Department of Prosthodontics, New York University College of Dentistry, New York, USA

2. Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, USA

Abstract

Aim: The aim of this study was to digitally measure the dimensional changes in an irreversible hydrocolloid impression material (alginate) resulting from varying storage times under optimal storage conditions. Materials and methods: A single type V dental stone control cast was used to make 25 alginate impressions using perforated stock trays. The impressions were randomly assigned into five groups of five samples each (n=5 per group) with varying storage times: Group 1, poured at 15 minutes; Group 2, poured at one hour; Group 3, poured at 24 hours (one day); Group 4, poured at 72 hours (three days); Group 5, poured at 168 hours (seven days). All impressions were stored in sealed Ziploc® plastic bags with a wet paper towel (100% relative humidity) at room temperature and stored according to the assigned group storage times. All impressions were poured in type V dental stone according to the manufacturer’s instructions. The casts were scanned with a digital 3D desktop scanner and saved as electronic stereolithography (.stl) files. Each .stl file of the scanned casts were superimposed on the .stl file of the control cast using Geomagic® Control X™ software. Three preselected fixed comparison measuring points (CMP) on each cast were compared to the control cast. Point one (CMP1) was on the midfacial surface of central incisor. Point two (CMP2) and point three (CMP3) were on the mesiobuccal proximal marginal ridge areas of third molars. The discrepancies between the files at each point were analysed with colour maps, and quantified (Table 1). The tolerance was set at ±10μm. CMP scores were analysed using one-way analysis of variance (ANOVA) and Kruskal-Wallis (K-W) non-parametric H tests. Results: Average gap distances across groups ranged from 0.04mm (seven-day group) to 0.06mm (one hour and 24-hour groups). Colour maps indicated increased dimensional change with increased storage time up to one day. After three days, shrinkage up to 139μm was measured. ANOVA results for CMP1 (F[4,20] = 1.65, p = 0.020) and CMP3 (F[4,20] = 0.44, p = −0.78) were not statistically significant. Similarly, K-W results for CMP2 were not significant (χ2= 3.62, p = 0.46). Conclusions: Under optimal storage conditions, there were no significant dimensional changes in casts poured from alginate up to seven days.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3