Predictors of long-term outcomes after polytetrafluoroethylene-covered stent-graft repair of peripheral arterial aneurysms, pseudo-aneurysms, and arterio-venous fistulas

Author:

Topcuoglu Osman Melih1ORCID,Altay Cetin Murat2,Alpar Ayhan3,Kucukay Fahrettin4

Affiliation:

1. Department of Radiology, Yeditepe University Medical School, Istanbul, Turkey

2. Department of Radiology, Karabuk Educational and Research Hospital, Karabuk, Turkey

3. Department of Radiology, Sancaktepe Educational and Research Hospital, Istanbul, Turkey

4. Department of Radiology, Osmangazi University Medical School, Eskisehir, Turkey

Abstract

Objectives To evaluate the primary patency rate at three years for the infra-aortic peripheral arterial pathologies treated with polytetrafluoroethylene-covered stent-grafts. Methods Patients treated with self-expandable polytetrafluoroethylene-covered stent-grafts for infra-aortic peripheral arterial aneurysms, pseudo-aneurysms, and arterio-venous fistulas were evaluated retrospectively. A total of 48 patients (35 male, 13 female; mean age: 53.8 ± 13.5) were included with 29.0 ± 16.5 months (median 27, range 4–70) mean follow-up period. The primary objective was to determine the primary patency rate at three years. The secondary objectives were to compare type and localization of pathology, and length and diameter of the stent-grafts with primary patency rate. Kaplan–Meier test was used as the main statistical method. Results Overall mean primary patency rate at three years was 77.10%. Polytetrafluoroethylene-covered stent-graft implantation in aneurysms had worse primary patency rate than pseudo-aneurysms and arterio-venous fistulas (66.6%, P = 0.03; 76.9%, P = 0.03; 88.2%, P = 0.01, respectively). Stent-graft location, length, and diameter are not associated with primary patency rate ( P > 0.05) but stent diameter is associated with better primary assisted and secondary patency rates ( P < 0.05). Conclusions Pathology of the lesion is associated with the long-term primary patency rate of polytetrafluoroethylene-covered stent-grafts but not the stent-graft location, length, or diameter. Stent diameter is associated with primary assisted and secondary patency rates.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3