Preoperative CT-scan-based sizing and in-stent restenosis in peripheral endovascular revascularizations

Author:

Kaladji Adrien123,Giovannetti Maximilien4,Pascot Remy1,Clochard Elodie1,Daoudal Anne1,Lucas Antoine123,Cardon Alain1

Affiliation:

1. CHU Rennes, Centre of Cardiothoracic and Vascular Surgery, Rennes, France

2. INSERM, Rennes, France

3. University Rennes 1, Signal and Image Processing Laboratory (LTSI), Rennes, France

4. Private Hospital of Saint Martin, Department of Vascular Surgery, Caen, France

Abstract

Objectives This study evaluates the effect of stent sizing with CT-scan on the incidence of restenosis in peripheral arterial disease. Methods This retrospective study included 59 patients with 66 arterial lesions who underwent a endovascular procedure for peripheral arterial disease between April 2013 and October 2013. All patients had de novo iliac or femoral lesions, were candidates for an endovascular procedure alone and underwent CTA preoperatively. The stent actually implanted, whose dimensions were chosen on the basis of the operator’s experience on an intraoperative 2D angiography, was compared to the “ideal” stent chosen retrospectively on the basis of precise lesion sizing by the preoperative CTA. Planning was considered “discordant” if there was a difference in length of more than 20 mm and/or a difference in diameter of more than 1 mm between the ideal stent and the actual stent. Results For iliac lesions, discordance essentially concerned stent diameter (36.1%), whereas stent length was the main reason for discordance for femoral lesions (36.7%). The median length of follow-up was 18 months (range 6–24). For iliac lesions, freedom from restenosis at 24 months was higher for patients with concordant planning (90% vs. 62.5%, p = 0.045). Most restenoses occurred in the external iliac artery, where there was a tendency towards oversizing of the implanted stent. For femoral lesions, the restenosis-free rate at 24 months was higher for patients with concordant planning (77.8% vs. 50%, p = 0.057). A multivariate analysis was conducted on the prediction of restenosis. Among factors, only discordant planning was found to be a significant predictor of restenosis with an odds ratio of 0.115 (95% confidence interval, 0.02–0.674; p = 0.016). Conclusion The absence of sizing for peripheral lesions engenders a tendency to choose the wrong stent, in particular in terms of diameter in iliac arteries and length in femoral arteries.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3