Can we replace computed tomography angiography by contrast-enhanced ultrasound in the surveillance of patients submitted to aortoiliac aneurysm repair?

Author:

Park Jong Hun1ORCID,Filho Alvaro Razuk1,Pires Ana Paula M1,Telles Gustavo José P1,Esteves Fernando P1,Caffaro Roberto Augusto1,Parrillo Eduardo F1

Affiliation:

1. Department of Vascular and Endovascular Surgery, Santa Casa de Sao Paulo Medical School, Prevent Senior Health Operator, Bela Vista, São Paulo, Brazil

Abstract

Objectives This study was designed for evaluation of CEUS (contrast-enhanced ultrasound) for the detection of endoleaks after EVAR (endovascular aortic aneurysms repair) as an alternative to CTA (computed tomography angiography), the gold standard in post-EVAR surveillance. Methods Post-EVAR surveillance of patients who underwent CEUS and CTA was retrospectively analyzed to compare the accuracy of CEUS compared to CTA. For that, the following parameters were analyzed: the largest aneurysm diameter, type of endoleaks, and the time elapsed after EVAR using both surveillance tests. Results The study involved 110 pairs of exams in patients with infrarenal aortoiliac or isolated iliac artery aneurysm, covering predominantly a male population (89%). The time elapsed after EVAR using CEUS or CTA exams were statistically similar, ranging from one to 58 months (mean 12.2) and one to 65 months (mean 9.7), respectively ( p = 0.124). CEUS sensitivity was 75.5%, specificity 96.7%, false positives were 24.5%, and false negatives were 3.3%. The accuracy between the two exams was 87.3%. A secondary analysis, comparing CTA with CEUS as a reference standard, revealed CEUS sensitivity of 24.5%, higher than CTA for detecting endoleaks, with a concordance rate of true positive results of 75.5%. Among the endoleaks detected solely by CEUS (12 cases), one case was type Ia and eleven were type II, while those detected only by CTA (2 cases), one was type Ia and one type II. Additionally, a type II endoleak associated with type Ib, identified by CEUS, was seen as type II for CTA only. There was no difference between the pre-EVAR and the post-EVAR diameters of aortoiliac aneurysm ( p = 0.058), both for CEUS and CTA. Computed tomography angiography, on the other hand, showed significant aneurysm diameter reduction compared to CEUS for isolated iliac artery aneurysms ( p < 0.001). Conclusion Contrast-enhanced ultrasound was more effective than CTA in identifying and characterizing endoleaks in patients undergoing EVAR, especially type II endoleaks. The advantages include efficacy and, particularly, safety, and must be considered in EVAR surveillance protocols so that its use becomes widespread. We understand that CEUS, as a surveillance exam, considerably reduces risks to patients compared to CTA.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3