Endoscopic Tendon Compression Bridge Technique for Repair of Partial-Thickness Gluteus Medius Tears With Concomitant Arthroscopy for Labral Tears: Minimum 2-Year Outcomes With Benchmark Control Group

Author:

Prabhavalkar Omkar N.1,Carbone Andrew D.1,Curley Andrew J.1,Padmanabhan Saiswarnesh1,Nerys Julio1,Domb Benjamin G.12ORCID

Affiliation:

1. American Hip Institute Research Foundation, Chicago, Illinois, USA

2. American Hip Institute, Chicago, Illinois, USA

Abstract

Background: The transtendinous technique has been used to treat partial-thickness gluteus medius tears in the setting of concomitant arthroscopy for labral tears. The tendon compression bridge technique for gluteus medius repair has been developed as an alternative method, providing several advantages; however, comparative studies between the 2 techniques are lacking in the literature. Purpose: (1) To evaluate the short-term patient-reported outcomes (PROs) of the tendon compression bridge technique and (2) to compare these findings with short-term PROs of the transtendinous technique. Study Design: Cohort study; Level of evidence, 3. Methods: Data were prospectively collected on patients who were followed for a minimum of 2 years after an endoscopic tendon compression bridge procedure for gluteus medius repair in the setting of concomitant hip arthroscopy for labral tears. The following PROs were collected preoperatively and postoperatively: modified Harris Hip Score, Nonarthritic Hip Score, Hip Outcome Score–Sports Specific Subscale, visual analog scale score for pain, and the International Hip Outcome Tool. Clinical outcomes were assessed using the Patient Acceptable Symptom State, minimal clinically important difference, and maximum outcome improvement satisfaction threshold. Patients were propensity matched 1:1 to a cohort that underwent gluteus medius repair using the endoscopic transtendinous technique with concomitant hip arthroscopy. Results: A total of 48 hips (48 patients) that met inclusion criteria (age, 53.3 ± 9.8 years; 92% female; body mass index, 26.7 ± 4.6), with a mean follow-up of 38.5 ± 15.7 months, were matched to 48 hips (46 patients) that underwent gluteus medius repair using the transtendinous technique. Both groups demonstrated significant improvement from preoperative scores to latest follow-up ( P < .05). Mean magnitude of improvement and latest follow-up scores were not significantly different between the tendon compression bridge group and the transtendinous group, and the groups demonstrated similar favorable rates of achieving Minimal Clinically Important Difference (79% vs 79%, respectively), Patient Acceptable Symptom State (73% vs 73%, respectively), and Maximum Outcome Improvement Satisfaction threshold (65% vs 58%, respectively) for modified Harris Hip Score ( P > .05). Patient satisfaction between groups was similar (8.1 ± 2.2 vs 7.7 ± 2.7, respectively) ( P = .475). Conclusion: At minimum 2-year follow-up, the endoscopic tendon compression bridge technique for partial-thickness gluteus medius tears, when performed with concomitant hip arthroscopy, was associated with significant improvement in functional outcomes. These postoperative results were comparable with those of a matched cohort that underwent the endoscopic transtendinous technique for partial-thickness gluteus medius tears, suggesting that the tendon compression bridge technique for gluteus medius repair is an effective treatment option for partial-thickness gluteus medius tears.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3