Suspensory Versus Interference Tibial Fixation of Hamstring Tendon Autografts in Anterior Cruciate Ligament Reconstruction: Results From the New Zealand ACL Registry

Author:

Rahardja Richard1ORCID,Love Hamish2,Clatworthy Mark G.3,Monk Andrew P.14,Young Simon W.15

Affiliation:

1. Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand

2. Forte Sports, Christchurch, New Zealand

3. Department of Orthopaedic Surgery, Middlemore Hospital, Auckland, New Zealand

4. Department of Orthopaedic Surgery, Auckland Hospital, Auckland, New Zealand

5. Department of Orthopaedic Surgery, North Shore Hospital, Auckland, New Zealand

Abstract

Background: The hamstring tendon is frequently used to reconstruct the anterior cruciate ligament (ACL), but there is a lack of consensus on the optimal method of fixation. Registry studies have shown that the type of femoral fixation device can influence the risk of revision ACL reconstruction (ACLR), but it is unclear whether the type of tibial fixation has an effect. In New Zealand, over 95% of hamstring tendon grafts are fixed with an adjustable loop suspensory device on the femoral side, with variable usage between suspensory and interference devices, with or without a sheath, on the tibial side. Purpose: To investigate the association between the type of tibial fixation device and the risk of revision ACLR. Study Design: Cohort Study; Level of evidence, 2. Methods: Prospective data recorded in the New Zealand ACL Registry were analyzed. Only primary ACLRs performed with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. A Cox regression survival analysis with adjustment for patient factors was performed to analyze the effects of the type of tibial fixation device, the number of graft strands, and graft diameter on the risk of revision. Results: A total of 6145 primary ACLRs performed between 2014 and 2019 were analyzed. A total of 59.6% of hamstring tendon autografts were fixed with a suspensory device on the tibial side (n = 3662), 17.6% with an interference screw with a sheath (n = 1079), and 22.8% with an interference screw without a sheath (n = 1404). When compared with suspensory devices, a higher revision risk was observed when using an interference screw with a sheath (adjusted hazard ratio [HR], 2.05; P = .009) and without a sheath (adjusted HR, 1.81; P = .044). The number of graft strands and a graft diameter of ≥8 mm were associated with the rate of revision on the univariate analysis; however, after adjusting for confounding variables on the multivariate analysis, they did not significantly influence the risk of revision. Conclusion: In this study of hamstring tendon autografts fixed with an adjustable loop suspensory device on the femoral side during primary ACLR, the use of an interference screw, with or without a sheath, on the tibial side resulted in a higher revision rate when compared with a suspensory device.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3