Comparative Study of Navigated versus Freehand Osteochondral Graft Transplantation of the Knee

Author:

Koulalis Dimitrios12,Di Benedetto Paolo13,Citak Mustafa1,O'Loughlin Padhraig1,Pearle Andrew D.1,Kendoff Daniel O.1

Affiliation:

1. Orthopaedic Department, Hospital for Special Surgery, New York, New York

2. First Orthopaedic Department, University of Athens, Attikon Hospital, Athens, Greece

3. Clinica Ortopedica e Traumatologica, Università degli Studi di Udine, Italy

Abstract

Background Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Hypothesis Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Study Design Controlled laboratory study. Methods Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. Results The mean harvesting angle at the donor site using navigation was 4° (standard deviation, 2.3°; range, 1°-9°) versus 12° (standard deviation, 5.5°; range, 5°-24°) using freehand technique ( P < .0001). The recipient plug removal angle using the navigated technique was 3.3° (standard deviation, 2.1°; range, 0°-9°) versus 10.7° (standard deviation, 4.9°; range, 2°-17°) in freehand ( P < .0001). The mean navigated recipient plug placement angle was 3.6° (standard deviation, 2.0°; range, 1°-9°) versus 10.6° (standard deviation, 4.4°; range, 3°-17°) with freehand technique ( P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique ( P = .0034). Conclusion Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Clinical Relevance Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3