The effects of processing techniques on the mechanical properties of bone-anterior cruciate ligament-bone allografts

Author:

Jackson D.W.1,Grood E.S.2,Wilcox P.3,Butler D.L.2,Simon T.M.1,Holden J.P.2

Affiliation:

1. Southern California Center for Sports Medicine Long Beach, California

2. Noyes-Giannestras Biomechanics Laboratory, Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, Ohio

3. Progressive Orthopaedics, Inc., Akron, Ohio

Abstract

There has been a growing interest in the use of allo grafts as ACL substitutes. Allografts are often freeze dried to increase shelf storage time and sterilized with ethylene oxide. This study was conducted to determine the effect of a specific ethylene oxide sterilization pro cedure and freeze drying process on the initial mechan ical properties of femur-ACL-tibia preparations. Twelve knees (stifle joints) from six mature goats were divided into two groups (one knee of pair to each group). Knees were cleaned of all soft tissue except for the anterior cruciate, posterior cruciate, and collateral ligaments. Group 1 was sterilized with ethylene oxide (simulating clean procurement) then freeze dried. Group 2 was freeze dried only (simulating sterile procurement). The knees were rehydrated and then tested in tension to failure to determine their structural mechanical proper ties. The ethylene oxide-freeze dried specimens (Group 1) had a mean maximum load before failure of 2059 ± 273 newtons (N) (± SE) which was not statistically different than the maximum load of the freeze dried specimens (Group 2) of 2023 ± 214 N. The average strength of Group 1 and 2 combined was not signifi cantly different than a third group of 12 normal femur- ACL-tibia controls which had an average maximum force of 2403 ± 133 N. No significant differences be tween the groups were observed for stiffness, energy to maximum strength, or elongation to maximum force. It appears the freeze dry processing, with or without ethylene oxide sterilization, using the procedure we used, has, at most, a small effect on the initial mechan ical properties of the preparations. The low mechanical properties of implanted and revascularized allografts, as compared to normal femur-ACL-tibia complex ap pears to be related more to fixation strength and alter ations which occur in the ligament substance after implantation.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3