Accuracy Analysis of a Novel Electromagnetic Navigation Procedure Versus a Standard Fluoroscopic Method for Retrograde Drilling of Osteochondritis Dissecans Lesions of the Knee

Author:

Hoffmann Michael12,Petersen Jan Philipp12,Schröder Malte2,Hartel Maximillian2,Kammal Michael3,Rueger Johannes Maria2,Ruecker Andreas Hermann2

Affiliation:

1. Both authors contributed equally and therefore share first authorship

2. Department of Trauma, Hand and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

3. Department of Forensic Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

Abstract

Background: Retrograde drilling for osteochondritis dissecans (OCD) remains a challenging operation. Purpose: A novel radiation-free electromagnetic navigation system (ENS)–based method was developed and its feasibility and accuracy for retrograde drilling procedures evaluated and compared with the standard freehand fluoroscopic method in an experimental setting. Study Design: Controlled laboratory study. Methods: A controlled laboratory study with 16 standard freehand fluoroscopically and 16 electromagnetically guided retrograde drilling procedures was performed on 8 cadaveric human knees. Four artificial cartilage lesions (2 on each condyle) were set per knee. Drilling accuracy was determined by final distance from the tip of the drill bit to the tip of the probe hook (D1) and distance between the tip of the drill and the marked lesion on the cartilage surface (D2). Intraoperative fluoroscopy exposure times were documented, as were directional readjustments or complete restarts. All procedures were timed using a stopwatch. Results: Successful retrograde drilling was accomplished in all 16 cases using the novel ENS-based method and in 11 cases using the standard fluoroscopic technique. The overall mean time for the fluoroscopy-guided procedures was 10 minutes 55 seconds ± 3 minutes 19 seconds and for the ENS method was 5 minutes 34 seconds ± 38 seconds, providing a mean time benefit of 5 minutes 35 seconds ( P < .001). Mean D1 was 3.8 ± 1.6 mm for the standard and 2.3 ± 0.6 mm using the ENS technique ( P = .021), and mean D2 was 2.5 ± 1.3 mm for the standard and 0.9 ± 0.7 mm for the ENS-based method ( P < .001). Conclusion: Compared with the standard fluoroscopic technique, the novel ENS-based method used in this study showed superior accuracy, required less time, and utilized no radiation. Clinical Relevance: The novel method improves a standard operating procedure in terms of accuracy, operation time for the retrograde drilling procedure, and radiation exposure.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine