The Hip Suction Seal, Part I: The Role of Acetabular Labral Height on Hip Distractive Stability

Author:

Storaci Hunter W.1,Utsunomiya Hajime1,Kemler Bryson R.1,Rosenberg Samuel I.1,Dornan Grant J.1,Brady Alex W.1,Philippon Marc J.12

Affiliation:

1. Steadman Philippon Research Institute, Vail, Colorado, USA

2. The Steadman Clinic, Vail, Colorado, USA

Abstract

Background: The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known. Hypothesis: The smaller height of acetabular labrum is associated with decreased distractive stability. Study Design: Descriptive laboratory study. Methods: A total of 23 fresh-frozen cadaveric hemipelvises were used in this study. Hips with acetabular dysplasia or femoroacetabular impingement–related bony morphologic features, intra-articular pathology, or no measurable suction seal were excluded. Before testing, each specimen’s hip capsule was removed, a pressure sensor was placed intra-articularly, and the hip was fixed in a heated saline bath. Labral size was measured by use of a digital caliper. Maximum distraction force, distance to suction seal rupture, and peak negative pressure were recorded while the hip underwent distraction at a rate of 0.5 mm/s. Correlations between factors were analyzed using the Spearman rho, and differences between groups were detected using Mann-Whitney U test. Results: Of 23 hips, 12 satisfied inclusion criteria. The maximum distraction force and peak negative pressure were significantly correlated ( R = −0.83; P = .001). Labral height was largely correlated with all suction seal parameters (maximum distraction force, R = 0.69, P = .013; distance to suction seal rupture, R = 0.55, P = .063; peak negative pressure, R = −0.62, P = .031). Labral height less than 6 mm was observed in 5 hips, with a mean height of 6.48 mm (SD, 2.65 mm; range, 2.62-11.90 mm; 95% CI, 4.80-8.17 mm). Compared with the 7 hips with larger labra (>6 mm), the hips with smaller labra had significantly shorter distance to suction seal rupture (median, 2.3 vs 7.2 mm; P = .010) and significantly decreased peak negative pressure (median, −59.3 vs −66.9 kPa; P = .048). Conclusion: Smaller height (<6 mm) of the acetabular labrum was significantly associated with decreased distance to suction seal rupture and decreased peak negative pressure. A new strategy to increase the size of the labrum, such as labral augmentation, could be justified for patients with smaller labra in order to optimize the hip suction seal. Clinical Relevance: The height of the acetabular labrum is correlated with hip suction seal biomechanics. Further studies are required to identify the clinical effects of labral height on hip stability.

Funder

smith and nephew

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3