The Use of End-tidal Carbon Dioxide Monitoring to Confirm Endotracheal Tube Placement in Adult and Paediatric Intensive Care Units in Australia and New Zealand

Author:

Erasmus P. D.12

Affiliation:

1. Intensive Care Unit, Royal Perth Hospital, Perth, Western Australia

2. Department of Anaesthetics, Royal Bournemouth and Christchurch Hospitals NHS Trust, Bournemouth, U.K.

Abstract

The use of end-tidal carbon dioxide monitoring to assist in confirming endotracheal tube placement is currently not mandatory in intensive care units (ICUs) in Australia and New Zealand. Early detection of failed tracheal intubation is vital to optimize management and to prevent complications. Questionnaires were sent to the lead clinician/head of department of all 66 intensive care units approved for training purposes by the Joint Faculty of Intensive Care Medicine in Australia and New Zealand. The methods used to confirm correct endotracheal tube placement, the availability of end-tidal carbon dioxide monitoring and its role in confirming endotracheal tube placement in the intensive care unit were explored. Completed questionnaires were received from 61 of the 66 centres (92.4%). Wide variation in the method of confirmation of endotracheal tube position was demonstrated, with 23 (37.7%) of units using sub-optimal methods. Sixty (98.3%) of units had end-tidal carbon dioxide monitoring available. Thirty-eight (62%) units shared monitors between several beds; and 22 (36%) had one monitor per bed. End-tidal carbon dioxide monitoring was used routinely to confirm endotracheal tube placement in 42 (68.8%) units. Fifty-two respondents (83.3%) felt that end-tidal carbon dioxide monitoring was superior to other methods for confirming endotracheal tube placement in critically ill patients. Thirty-eight respondents (62.3%) thought that end-tidal carbon dioxide monitoring should be mandatory to confirm tracheal intubation in the intensive care unit. If it were available, 42 respondents (68.8%) would use end-tidal carbon dioxide monitoring for confirmation of every intubation. Mandatory end-tidal carbon dioxide confirmation of endotracheal tube placement was policy in 33 (54.1%) of the intensive care units.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3