A review of medical devices used for safe chemotherapy applications: Focus on ONCOERA® IV GROUP products

Author:

Tekin Kemal1,Karadoğan Muhammed1,Kismet Kemal2ORCID

Affiliation:

1. Q MEN Informatics Software Consulting Education Ltd, Ankara, Turkey

2. Freelancer, Ankara, Turkey

Abstract

Objective The healthcare workers and the workers in the manufacturing industry of chemotherapy drugs are exposed to the “hazardous” effects of these drugs during production, transportation, distribution, administration, and disposal. In order to be protected from these harmful effects, personal protective equipment and medical devices providing safe applications are used. The aim of the present article is to review of medical devices used for safe chemotherapy applications in line with the information obtained from the literature. Data sources The international and national reliable sources, were used in the literature review for data analysis by using the keywords including chemotherapy, chemotherapy drugs, antineoplastic drugs, cytotoxic drugs, hazardous drugs, exposure to chemotherapy drugs, side effects of chemotherapy drugs, closed-system drug transfer devices, healthcare staff, needle-free devices, needle-free connectors, surface contamination, and phthalates. Data summary In order to minimize cytotoxic drug exposure, international standards were developed in the mid-1980s stating that all cytotoxic drugs should be prepared preferably in a ventilated biological safety cabinet, nurses dealing with the use of these drugs should use appropriate personal protective equipment, and in case of cytotoxic drug spillage, predefined cleaning and decontamination protocols should be followed. Although the risk of acute and long-term toxic effects in healthcare workers has decreased in recent years with these applications in the preparation and administration of cancer drugs, measurable contamination occurs in the workplace. A large number of medical devices have been developed for minimizing this type of contamination with chemotherapy drugs. In this article, these medical devices have been reviewed in detail under subtitles of closed system transfer devices, needle-free devices, and valve technology. Conclusions Until the results of the evaluations to be made in new studies prove the opposite, the use of these devices with additional protection measures taken, especially during the application of dangerous drugs, is of great importance in terms of patient and employee safety.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Oncology

Reference21 articles.

1. Are health care providers who work with cancer drugs at an increased risk for toxic events? A systematic review and meta-analysis of the literature

2. Avoiding accidental exposure to intravenous cytotoxic drugs

3. Connor TH, MacKenzie BA, DeBord DG, et al. NIOSH list of antineoplastic and other hazardous drugs in healthcare settings, 2016. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication Number 2016-161 (Supersedes 2014-138).

4. The all-glass Lüer syringe: Historical facts around concepts, introduction and patents

5. An evaluation of chemotherapy drug preparation process in hospitals in Turkey – A pilot study

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3