The Red Blood Cell Phototoxicity Test (Photohaemolysis and Haemoglobin Oxidation): EU/COLIPA Validation Programme on Phototoxicity (Phase II)

Author:

Pape Wolfgang J.W.1,Maurer Thomas2,Pfannenbecker Uwe1,Steiling Winfried3

Affiliation:

1. Beiersdorf AG, Unnastrasse 48, 20245 Hamburg, Germany;

2. Novartis Pharma AG, 4002 Basel, Switzerland

3. Henkel KgaA, 40191 Düsseldorf, Germany

Abstract

In the EU/COLIPA validation programme on “Photoirritation in vitro”, two core tests and a number of mechanistically based tests were carried out to examine their suitability as regulatory tests for phototoxicity testing. In the meantime, one core test, the 3T3 neutral red uptake phototoxicity test (NRU PT) has been validated and has been accepted by ECVAM and the European Commission. The second core test, the red blood cell phototoxicity test (Photo-RBC test), has passed through a prevalidation process during this programme. This test protocol combines two endpoints, photohaemolysis and met-haemoglobin (met-Hb) formation. These endpoints are determined by measuring changes in the optical density of the haemoglobin spectrum at 525nm and 630nm, respectively. In addition, a prediction model was inserted into the Standard Operating Procedure (SOP) with two cut-off values: a photohaemolysis factor (PHF) ≥ 3.0 for photohaemolysis, and a ΔODmax ≥ 0.05 for met-Hb formation. Three laboratories agreed to implement the SOP and to perform the study by testing 30 selected test chemicals (25 phototoxicants and 5 non-phototoxic chemicals). The outcome of the study presents a good overall fit, including acceptable accuracy, sensitivity, and positive predictivity. The specificity and the negative predictivity are comparably low, due to the low number of non-phototoxic substances among the test chemicals. Further analysis of the data showed that the transfer of the SOP from between laboratories could have been more efficient. The results, especially of the lead laboratory, clearly indicate that an experienced laboratory can handle the SOP with high predictivity for phototoxicants and non-phototoxic substances. Finally, it was concluded that the combined Photo-RBC test can be considered as a second in vitro test, which can be used advantageously to obtain some mechanistic information, in particular on photodynamic effects on cellular proteins and biomembranes.

Publisher

SAGE Publications

Subject

Medical Laboratory Technology,Toxicology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3