Virtual monoenergetic dual-energy CT reconstructions at 80 keV are optimal non-contrast CT technique for early stroke detection

Author:

Dodig Doris1ORCID,Matana Kaštelan Zrinka12,Bartolović Nina1,Jurković Slaven34,Miletić Damir12,Rumboldt Zoran2

Affiliation:

1. Radiology Department, Clinical Hospital Centre Rijeka, Croatia

2. Department of Radiology, University of Rijeka, Croatia

3. Department of Medical Physics and Biophysics, University of Rijeka, Croatia

4. Department for Medical Physics and Radiation Protection, Clinical Hospital Centre Rijeka, Croatia

Abstract

Background Virtual monoenergetic (VM) dual-energy computed tomography (DE-CT) enables grey-to-white matter contrast-to-noise ratio optimization, potentially increasing ischaemic brain oedema visibility. The aim of this study was to compare the diagnostic accuracy of VM and standard DE-CT reconstructions for early stroke detection. Methods Consecutive patients with non-contrast DE-CT of the brain scanned within 12 h of stroke symptom onset were prospectively included in the study. Patients with other significant brain pathology were excluded. Two radiologists jointly evaluated standard and VM reconstructions (from 40 to 190 keV at increments of 10 keV) for early stroke signs on a four-point Likert scale: (a) stroke definitely present, (b) stroke probably present, (c) probably no stroke, and (d) definitely no stroke. Follow-up imaging and clinical data served as the standard of reference. Diagnostic accuracy was evaluated by receiver operating characteristic analysis. Results Stroke incidence among 184 patients was 76%. In 64 patients follow-up imaging served as the standard of reference: ischemic brain oedema detection was significantly more accurate on VM reconstructions at 80 keV compared with standard DE-CT reconstructions (area under the curve (AUC) = 0.821 vs. AUC = 0.672, p = 0.002). The difference was most prominent within the first 3 h after symptom onset (at 11%, AUC = 0.819 vs. AUC = 0.709, p = 0.17) and in patients with National Institutes of Health Stroke Scale above 16 (at 37.5%, AUC = 1 vs. AUC = 0.625, p = 0.14). Conclusion VM DE-CT reconstructions at 80 keV appear to be the optimal non-contrast CT technique for diagnosing early ischaemic stroke, particularly within the first 3 h after symptom onset and in severely ill patients.

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3