Handmade Bicuspid Valved Polytetrafluoroethylene Conduit for Right Ventricular Outflow Tract Reconstruction

Author:

Malankar Dhananjay P.1,Dhake Shyam2,Mhatre Amit2,Soni Bharat1,Kandavel Dinesh1,Bamne Sujit3,Garekar Swati4

Affiliation:

1. Department of Paediatric Cardiac Surgery, Fortis Paediatric and Congenital Heart Centre, Mulund, Mumbai, India

2. Department of Paediatric Cardiac Anaesthesia and Critical Care, Fortis Paediatric and Congenital Heart Centre, Mulund, Mumbai, India

3. Department of Perfusion Technology, Fortis Paediatric and Congenital Heart Centre, Mulund, Mumbai, India

4. Department of Paediatric Cardiology, Fortis Paediatric and Congenital Heart Centre, Mulund, Mumbai, India

Abstract

Background: Excellent outcomes of right ventricle to pulmonary artery conduits with polytetrafluoroethylene (PTFE) valves have been reported. The purpose of this study was to analyze the short-term results of our handmade PTFE bicuspid valved conduit (VC) for right ventricular outflow tract reconstruction. Methods: Between September 2019 and May 2023, bicuspid PTFE-VC was implanted in 17 patients at a median age of 2.5 years (range, 3 months to 13.6 years). The PTFE-VC was fashioned from a commercially available PTFE tube graft (14 mm in three patients, 16 mm in three patients, 18 mm in one patient, 20 mm in three patients, and 22 mm in seven patients) and 0.1 mm thick PTFE membrane for the leaflet material. Valve function was assessed by echocardiogram after the implantation. The conduit reoperation and the conduit dysfunction were analyzed. There were no early deaths, but there was one late death. Results: There were no postoperative in-hospital deaths. Follow-up echocardiograms were available for 14 of 17 patients. The median follow-up was 21 months (range, 7-49 months). Conduit stenosis was none or trivial in 11 patients while it was mild in two and moderate in one patient and severe in 0 patients. Conduit insufficiency was mild or trivial in all 14 patients. By the end of the study period, freedom from reoperation/reintervention was 100%. There were no episodes of aneurysmal dilatation of the conduit or endocarditis. Conclusions: Handmade bicuspid PTFE VC shows good short-term outcome, with no significant valve dysfunction and no reintervention. A longer follow-up is necessary to evaluate the long-term advantages of using the handmade bicuspid PTFE VC.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3