Optimization of the Assisted Bidirectional Glenn Procedure for First Stage Single Ventricle Repair

Author:

Verma Aekaansh1,Esmaily Mahdi23,Shang Jessica4,Figliola Richard5,Feinstein Jeffrey A.67,Hsia Tain-Yen8,Marsden Alison L.679

Affiliation:

1. Department of Mechanical Engineering, Stanford University, Stanford, CA, USA

2. Center for Turbulence Research, Stanford University, Stanford, CA, USA

3. Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA

4. Department of Mechanical Engineering, University of Rochester, Rochester, NY, USA

5. Department of Mechanical Engineering, Clemson University, Clemson, SC, USA

6. Department of Pediatrics, Stanford University School of Medicine, Lucile Salter Packard Children’s Hospital, Palo Alto, CA, USA

7. Department of Bioengineering, Stanford University, Stanford, CA, USA

8. Cardiothoracic Unit, Great Ormond Street Hospital for Children NHS-Trust, London, UK

9. Institute for Computational and Mathematical Engineering, Stanford University, CA, USA

Abstract

Background: First-stage single-ventricle palliation is challenging to manage, and significant interstage morbidity and mortality remain. Prior computational and in vitro studies of the assisted bidirectional Glenn (ABG), a novel first-stage procedure that has shown potential for early conversion to a more stable augmented Glenn physiology, demonstrated increased pulmonary flow and oxygen delivery while decreasing cardiac work, as compared to conventional stage-1 alternatives. This study aims to identify optimal shunt designs for the ABG to improve pulmonary flow while maintaining or decreasing superior vena caval (SVC) pressure. Methods: A representative three-dimensional model of a neonatal bidirectional Glenn (BDG) was created, with a shunt connecting the innominate artery to the SVC. The shunt design was studied as a six-parameter constrained shape optimization problem. We simulated hemodynamics for each candidate designs using a multiscale finite element flow solver and compared performance against designs with taper-less shunts, the standalone BDG, and a simplified control volume model. Three values of pulmonary vascular resistance (PVR) of 2.3, 4.3, and 7.1 WUm2 were studied. Results: Increases in pulmonary flow were generally accompanied by increases in SVC pressure, except at low PVR (2.3 WUm2), where the optimal shunt geometry achieved a 13% increase in pulmonary flow without incurring any increase in SVC pressure. Shunt outlet area was the most influential design parameter, while others had minimal effect. Conclusion: Assisted bidirectional Glenn performance is sensitive to PVR and shunt outlet diameter. An increase in pulmonary flow without a corresponding increase in SVC pressure is possible only when PVR is low.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health,Surgery

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3