Daily Stereotactic Ultrasound Prostate Targeting: Inter-user Variability

Author:

Fuss Martin1,Cavanaugh Sean X.12,Fuss Cristina3,Cheek Dennis A.24,Salter Bill J.14

Affiliation:

1. Dept. of Radiation Oncology

2. Division of Radiological Sciences University of Texas Health Science Center at San Antonio 7703 Floyd Curl Drive San Antonio, TX 78229, USA

3. Dept. of Radiology

4. Cancer Therapy and Research Center 7979 Wurzbach San Antonio, TX, 78229, USA

Abstract

We analyzed the inter-user variability of patient setup for prostate radiotherapy using a stereotactic ultrasound-targeting device. Setup variations in 20 prostate cancer patients were analyzed. Users were a radiation oncologist, a medical physicist, four radiation technologists (RTT) and a radiologist. The radiation oncologist, radiologist, physicist and two RTTs were experienced users of the system (>18 months of experience); two RTTs were users new to the system. Gold standard for this analysis was a control CT acquired immediately following ultrasound targeting. For inter-user variability assessments, the radiation oncologist provided a set of axial and sagittal freeze-frames (standard freeze-frames) for virtual targeting by all users. Additionally each user acquired individual freeze-frames for target alignments. We analyzed the range of virtual setups in each patient along the principal room axes based on standard and individual freeze-frames. The magnitude of residual setup error and percentage of setup change for each user was assessed by control CT/planning CT comparison with individual virtual shifts. A total of 184 alignments were analyzed. The range of virtual shifts between users was 2.7±1.4, 3.6±1.1, and 4.4±1.4 mm (mean±SD) in x, y and z-direction for setups based on standard freeze-frames and 3.9±2.6, 6.0±4.7, and 5.4±2.7 mm for setups based on individual freeze-frames. When only virtual shifts of experienced users were analyzed, the mean ranges were reduced by up to 2.4 mm. Average magnitude of initial setup error before ultrasound targeting was 14.3 mm. Average improvement of prostate setup was 63.1±23.4% in experienced and 35.14±37.7% in inexperienced users, respectively (p<0.0001). Only 5 of 184 (2.7%) virtual alignments would have introduced new larger setup errors (mean 3.2 mm, range 0.2 to 9.5 mm) than the magnitude of the initial setup error. We conclude that ultrasound guided treatment setup for patients treated for prostate cancer can be performed with high inter-user consistency and does lead to improved treatment setup in more than 97% of attempted setups. Experienced use is correlated with a reduced range of setups between users and higher degree of setup improvement when compared with users new to the system.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3