Reducing variability in apparent operative inclination during total hip arthroplasty: findings of a randomised controlled trial

Author:

O’Neill Christopher K J1,Hill Janet C1,Patterson Christopher C2,Molloy Dennis O1,Gill Harinderjit S3,Beverland David E1

Affiliation:

1. Primary Joint Unit, Musgrave Park Hospital, Belfast - UK

2. Centre for Public Health, Queen’s University Belfast, Belfast - UK

3. Department of Mechanical Engineering, University of Bath, Bath - UK

Abstract

Aims: To determine which of 3 methods of cup insertion most accurately achieved a target apparent operative inclination (AOI) of 35° ± 2.5°: (1) Freehand; (2) Modified Mechanical Alignment Guide (MAG); or (3) Digital Inclinometer assisted. Methods: Using a cementless cup via a posterior approach in lateral decubitus 270 participants were recruited, with 90 randomised to each method. The primary outcome was the unsigned deviation from target AOI. The digital inclinometer was used to measure AOI in all cases, though the surgeon remained blinded to the reading intraoperatively for both the Freehand and MAG methods. Results: Mean deviation from target AOI for the Freehand, Modified 35° MAG and Digital Inclinometer techniques was 2.9°, 1.8° and 1.3° respectively. When comparing mean deviation from target AOI, statistically significant differences between the Freehand / Inclinometer groups ( p < 0.001), the Freehand / Modified 35° MAG groups ( p < 0.001) and the Digital Inclinometer / Modified 35° MAG groups ( p < 0.023) were evident. The Digital Inclinometer technique enabled the surgeon to achieve a target AOI of 35° ± 2.5° in 88% of cases, compared to 71% of Modified 35° MAG cases and only 51% of Freehand cases. Discussion: The Digital Inclinometer and the Modified 35° MAG techniques were both more accurate than the Freehand technique, with the Digital Inclinometer technique proving most accurate overall. Radiographic inclination (RI) is also influenced by operative anteversion; however, the greatest source of error with respect to RI occurs when the pelvic sagittal plane is not horizontal at the time of acetabular component insertion. Clinical Trial Protocol number: NCT01831401

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3