Effects of conform, non-conform, and hybrid conformity toward stress distribution at the glenoid implant and cement: A finite element study

Author:

Abdul Wahab Abdul Hadi12ORCID,Mohamad Azmi Nor Aqilah3,Abdul Kadir Mohammed Rafiq3,Md Saad Amir Putra34

Affiliation:

1. Centre for Multimodal Signal Processing, Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Tunku Abdul Rahman University College, Setapak, Kuala Lumpur, Malaysia

2. Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Tunku Abdul Rahman University College, Setapak, Kuala Lumpur, Malaysia

3. Medical Devices and Technology Centre, Institute of Human Centered Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia

4. Applied Mechanics and Design, School of Mechanical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia

Abstract

Glenoid conformity is one of the important aspects that could contribute to implant stability. However, the optimal conformity is still being debated among the researchers. Therefore, this study aims to analyze the stress distribution of the implant and cement in three types of conformity (conform, non-conform, and hybrid) in three load conditions (central, anterior, and posterior). Glenoid implant and cement were reconstructed using Solidwork software and a 3D model of scapula bone was done using MIMICS software. Constant load, 750 N, was applied at the central, anterior, and posterior region of the glenoid implant which represents average load for daily living activities for elder people, including, walking with a stick and standing up from a chair. The results showed that, during center load, an implant with dual conformity (hybrid) showed the best (Max Stress—3.93 MPa) and well-distributed stress as compared to other conformity (Non-conform—7.21 MPa, Conform—9.38 MPa). While, during eccentric load (anterior and posterior), high stress was located at the anterior and posterior region with respect to the load applied. Cement stress for non-conform and hybrid implant recorded less than 5 MPa, which indicates it had a very low risk to have cement microcracks, whilst, conform implant was exposed to microcrack of the cement. In conclusion, hybrid conformity showed a promising result that could compromise between conform and non-conform implant. However, further enhancement is required for hybrid implants when dealing with eccentric load (anterior and posterior).

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering