Functional Evaluation of the Endotics System, a New Disposable Self-Propelled Robotic Colonoscope: in vitro tests and clinical trial

Author:

Cosentino Felice1,Tumino Emanuele2,Passoni Giovanni Rubis1,Morandi Elisabetta3,Capria Alfonso2

Affiliation:

1. Gastroenterology and Digestive Endoscopy San Giuseppe Hospital, Milan - Italy

2. Gastroenterology Unit, Pisana University Hospital, Pisa - Italy

3. Digestive Endoscopy, San Paolo Hospital, Milan - Italy

Abstract

Objective Currently, the best method for CRC screening is colonoscopy, which ideally (where possible) is performed under partial or deep sedation. This study aims to evaluate the efficacy of the Endotics System, a new robotic device composed of a workstation and a disposable probe, in performing accurate and well-tolerated colonoscopies. This new system could also be considered a precursor of other innovating vectors for atraumatic locomotion through natural orifices such as the bowel. The flexible probe adapts its shape to the complex contours of the colon, thereby exerting low strenuous forces during its movement. These novel characteristics allow for a painless and safe colonoscopy, thus eliminating all major associated risks such as infection, cardiopulmonary complications and colon perforation. Methods An experimental study was devised to investigate stress pattern differences between traditional and robotic colonoscopy, in which 40 enrolled patients underwent both robotic and standard colonoscopy within the same day. Results The stress pattern related to robotic colonoscopy was 90% lower than that of standard colonoscopy. Additionally, the robotic colonoscopy demonstrated a higher diagnostic accuracy, since, due to the lower insufflation rate, it was able to visualize small polyps and angiodysplasias not seen during the standard colonoscopy. All patients rated the robotic colonoscopy as virtually painless com-pared to the standard colonoscopy, ranking pain and discomfort as 0.9 and 1.1 respectively, on a scale of 0 to 10, versus 6.9 and 6.8 respectively for the standard device. Conclusions The new Endotics System demonstrates efficacy in the diagnosis of colonic pathologies using a procedure nearly completely devoid of pain. Therefore, this system can also be looked upon as the first step toward developing and implementing colonoscopy with atraumatic locomotion through the bowel while maintaining a high level of diagnostic accuracy.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 58 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. MorphGI: A Self-Propelling Soft Robotic Endoscope Through Morphing Shape;Soft Robotics;2024-08-01

2. Painless colonoscopy: fact or fiction?;Clinical Endoscopy;2024-06-27

3. Ultra-minimally invasive endoscopic techniques and colorectal diseases: Current status and its future;Artificial Intelligence in Gastrointestinal Endoscopy;2024-06-08

4. A Novel, Flexible, Full-Length, Pressure-Sensing Sleeve for Colonoscopes;IEEE Sensors Journal;2024-02-01

5. A Colonoscopy Training Environment with Real-Time Pressure Monitoring;2023 IEEE Biomedical Circuits and Systems Conference (BioCAS);2023-10-19

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3