How well do we understand pulsatility in the context of modern ventricular assist devices?

Author:

Emmanuel Sam1234ORCID,Jansz Paul1234,Hayward Christopher124

Affiliation:

1. St Vincent’s Hospital (Sydney), Darlinghurst, NSW, Australia

2. School of Medicine, University of New South Wales, Sydney, Australia

3. School of Medicine, University of Notre Dame, Sydney, Australia

4. Victor Chang Cardiac Research Institute, Sydney, Australia

Abstract

Background: Modern ventricular assist devices (VADs) use a continuous flow design. It has been suggested that a lack of pulsatility contributes to a range of adverse outcomes including pump thrombus, gastrointestinal bleeding and stroke. To better assess the role of pulsatility in these adverse events, we first require a clear definition of ‘pulsatility’ in the setting of a severely impaired ventricle and a modern continuous flow VAD. Methods: A literature review was conducted to elucidate the understanding of pulsatility in modern VAD literature. Search engines used included PUBMED, EMBASE and the Cochrane library. Articles were appraised on three aspects: Whether they mentioned pulsatility; whether they mentioned which pulsatility measure was used and finally which methodology was used to obtain the value. Results: Of 354 articles reviewed, only 13 met our broad inclusion criteria. Of these articles, the most cited measure was pulsatility index (PI) – used by 11 of the publications. The methodology used to obtain the value was not uniform and five articles did not clearly state it. Other measures included pulse pressure and surplus haemodynamic energy. The majority of articles did not directly discuss pulsatility in the setting of patient-pump interaction. Conclusion: Most publications did not provide a definition for pulsatility. In those that did, the most common measure was PI. Measuring PI was not standardised. Few papers addressed the impact of intrinsic ventricular function and arterial compliance on pulsatility. We suggest that future publications adopt a uniform definition which encompasses both patient and pump characteristics.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3