Clinical Evaluation of Internal Hemodiafiltration (iHDF): A Diffusive-Convective Technique Performed with Internal Filtration Enhanced High-Flux Dialyzers

Author:

Lucchi L.1,Fiore G.B.2,Guadagni G.3,Perrone S.1,Malaguti V.1,Caruso F.1,Fumero R.2,Albertazzi A.1

Affiliation:

1. Department of Internal Medicine, Division of Nephrology and Dialysis, University Hospital, Modena - Italy

2. Department of Bioengineering, Politecnico di Milano, Milano - Italy

3. Estor SpA - Italy

Abstract

Aim Efficiency in removing middle molecules such as ß2-microglobulin (ß2-MG) is one of the main purposes of modern dialytic therapy. In order to achieve this, techniques requiring complex machines and substitution fluid have been developed over recent years. Alternatively, the internal filtration / back filtration phenomenon can be used. The recent development of a so-called “internal filtration enhanced dialyser” prompted us to compare the removal of ß2-MG together with other small molecules when the dialyser was used either in standard hemodiafiltration (HDF) or internal hemodiafiltration (iHDF). Methods Ten stable, anuric, hemodialysis (HD) patients treated by thrice weekly standard bicarbonate HD using low-flux synthetic membrane entered the study. A new high-flux polysulfone dialyser designed with the specific aim of enhancing internal filtration (BS-1.6 UL, 1.6 m2, Toray Industries) was used. Post dilution HDF (2.5 l/hour of substitution fluid, dialysate flow 500 ml/min) was compared with iHDF (dialysate flow 750 ml/min), with blood flow at 300 ml/min. Samples were obtained at the start and at the end of the session in order to measure the % removal of urea, creatinine, uric acid, phosphate and ß2-MG (corrected for total protein concentration). In addition, after 20 min of dialysis the clearances of the same molecules were measured. A mathematical model has been developed for the description of the hydrodynamic phenomena taking place within the dialyser and of fluid filtration across the membrane. Results No significant differences have been observed in removal rate switching from HDF to iHDF except for ß2-MG removal, which was slightly higher in HDF than in iHDF. Phosphate clearance is significantly higher than those obtained with creatinine in both HDF (p<0.005) and iHDF (p<0.01) modalities. The total convection calculated with the model is reduced with respect to HDF only by 24% (4100 ml/h vs. 5400 ml/h on the average). Conclusions iHDF is a high flux dialysis method, which, if performed with a dialyser designed to enhance internal filtration, obtains a much higher removal rate in comparison with dialysers in traditional high flux dialysis, as previously reported in the literature. Provided that the dialyser is used on a dialysis machine working with ultra pure dialysate and UF control, this dialyser line can perform reliable internal HDF without the need for replacement solution. Considering the narrow difference in performance observed between iHDF and HDF, and the increasing number (and age) of patients leading to higher dialysis costs, iHDF represents a cost-effective alternative to other diffusive-convective techniques.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3