Gas Exchange in a Virtual Respiratory System -Simulation of Ventilation without Lung Movement

Author:

Golczewski T.1

Affiliation:

1. Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw - Poland

Abstract

Aims The aim of this study was to supplement a previously developed virtual respiratory system (RS) with gas exchange and gas transfer in airways and circulation (GETAC); and to analyze arterial blood oxygenation during apnea when pure O2 is the ambient gas, with and without extracorporeal CO2 removal (ER), for different inspiratory O2 fractions (FiO2) before respiratory halt. Methods The virtual RS consists of the RS mechanics model and a model of GETAC consisting of three modules. The values of the model parameters correspond to the average values for a human being, which gave the “standard” virtual patient. This patient was artificially ventilated in supine position with FiO2=20%, 27%, and 34%, and then the respiration was stopped, FiO2 was changed to 99%, and ER was activated or not. The percent of oxygenated hemoglobin (HbO2%) and alveolar partial pressure of O2 (PAO2) were analyzed during 40 minutes after the beginning of apnea. Both cardiac output and oxygen consumption was assumed to be independent from HbO2%. Results Without ER, HbO2% decreased from 98% to 90% when FiO2=34% before apnea, while it decreased below the safety level (70%) for smaller FiO2. However, if ER was activated, HbO2% fell to 76%, 94%, and 97% from 95%, 97%, and 98%, respectively. For FiO2=27%, PAO2 was equal to 15.9, 15.1, 14.3, and 13.6 kPa after 10, 20, 30, and 40 minutes after the beginning of apnea, respectively. Thus, in the case of this particular (“standard”) patient, FiO2=27% before apnea and FiO2=99% during apnea provides proper blood oxygenation with approximately normal PAO2 if ER is activated. Conclusions If ER is available, it is possible to keep both sufficient blood oxygenation and a normal level of CO2 in the blood as well as a relatively low partial pressure of toxic O2 in the lungs without cyclic mechanical action on the diseased lungs or chest.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3