Introduction: Measurement of brain volume on magnetic resonance imaging (MRI) scans is regarded as an objective marker of multiple sclerosis (MS) severity with the potential to monitor treatment efficacy accurately. This study was performed to assess the variability of brain MRI volume measurements. Patients and methods: We studied nine patients with relapsing-remitting MS, who were imaged on two occasions (separated by an interval of 24 h) using two different MR scanners and fast fluid-attenuated inversion recovery (fast-FLAIR) sequences. The whole brain volume computed from each image was measured three times by three observers using a seed-growing technique based on signal intensity thresholding. Intra-observer, inter-observer and inter-scanner variabilities were expressed as coefficients of variations (COVs). The inter-scanner variability included not only the intra-observer variation but also the repositioning variability and the variation in observed brain volume caused by different scanner hardware and sequence implementations. Results: There was no statistically significant difference in patients' brain volume values between observers (P=0.82) or between scanners (P=0.30). The mean intra-observer COV was 1.2% (s.e.=0.4%), the mean inter-observer COV was 1.8% (s.e.=0.8%) and the mean inter-scanner COV was 2.4% (s.e.=1.2%). The intra-observer variance was not statistically different from those found between observers (P=0.83) or scanners (P=0.44). Conclusion: The intra-observer variability in brain volume measurements found in this study was within the range of intra-observer variability found in previous studies. This study shows that the use of different observers and MR scanners has only a small influence on the measured brain volume and does not affect the reproducibility of this measurement greatly.

Publisher

SAGE Publications

Subject

Neurology (clinical),Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3