Reproducibility of high-resolution optical coherence tomography in multiple sclerosis

Author:

Syc Stephanie B1,Warner Christina V1,Hiremath Girish S1,Farrell Sheena K1,Ratchford John N1,Conger Amy2,Frohman Teresa2,Cutter Gary3,Balcer Laura J4,Frohman Elliot M2,Calabresi Peter A5

Affiliation:

1. Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA

2. Departments of Neurology and Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA

3. Department of Biostatistics, University of Alabama at Birmingham, Birmingham, AL, USA

4. Departments of Neurology and Ophthalmology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA

5. Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA,

Abstract

Optical coherence tomography (OCT) is a non-invasive method to quantify neurodegeneration as an outcome in multiple sclerosis clinical trials; however, no data exist on Cirrus spectral domain optical coherence tomography (SD-OCT) reproducibility in patients with multiple sclerosis. The objective of this study was to determine the protocol for achieving optimal inter-visit, inter-rater, and intra-rater reproducibility for studies performed on healthy controls and multiple sclerosis patients utilizing novel high-definition SD-OCT. This is a prospective study of inter-visit, inter-rater, and intra-rater reproducibility in multiple sclerosis patients ( n = 58) and healthy controls ( n = 32) on Cirrus-HD SD-OCT. Excellent reproducibility of average and quadrantic retinal nerve fiber layer (RNFL) thickness values, average macular thickness (AMT), and total macular volume (TMV) [measured by intraclass correlation coefficient (ICC)] was found for inter-visit (healthy controls: mean RNFL = 0.97, quadrant range = 0.92—0.97, AMT = 0.97, TMV = 0.92), inter-rater (MS: mean RNFL = 0.97, quadrant = 0.94—0.98, AMT = 0.99, TMV = 0.96; healthy controls: mean RNFL = 0.97, quadrant = 0.94—0.97, AMT = 0.98, TMV = 0.99), and intra-rater (MS patients: mean RNFL = 0.99, quadrant = 0.83—0.99, AMT = 0.97, TMV = 0.98) reproducibility. The reproducibility of retinal measures derived by Cirrus HD-OCT, especially quadrantic values, is excellent. Specific procedures for OCT acquisition and analysis of retinal imaging metrics using SD-OCT technology may improve the application of this novel technology in multiple sclerosis.

Publisher

SAGE Publications

Subject

Neurology (clinical),Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3