Evaluation of the SmartClip™ Nonradioactive Seed, a Novel Wireless Localization Method for the Breast: Initial Clinical Experience and Surgical Outcome

Author:

Hefelfinger Leah1ORCID,Doherty Alexander1ORCID,Wahab Rifat2,Rosen Lauren3,Shaughnessy Elizabeth A.4,Lewis Jaime D.4

Affiliation:

1. College of Medicine, University of Cincinnati, Cincinnati, OH, USA

2. Department of Radiology, Division of Breast Imaging, University of Cincinnati, Cincinnati, OH, USA

3. Department of Pathology, Section of Surgical Pathology within the Division of Anatomic Pathology, University of Cincinnati, Cincinnati, OH, USA

4. Department of Surgery, Division of Surgical Oncology, University of Cincinnati, Cincinnati, OH, USA

Abstract

Introduction Wire localization has been the gold standard for breast localization of non-palpable lesions for decades. This technique remains robust but has disadvantages relative to scheduling, complications of vasovagal reactions in placement, wire migration, or transection. With more modern technologies available, several implantable markers have been developed to allow uncoupling of localization by radiology and the surgical procedure on the same day. This study summarizes our experience with the EnVisio Navigation System™ utilizing SmartClip™ as the implantable tissue localization marker. Methods An IRB-approved retrospective database of benign and malignant breast disease was used to perform a review of 100 consecutive patients who underwent SmartClip™ localized breast and axillary procedures in 2021. Demographic information, localization accuracy, associated surgical procedure(s) with resultant pathology findings, margin status for malignancies, and re-excision rate were collected. Results The localized breast lesion or lymph node was excised and SmartClip™ retrieved in all cases, confirmed by intraoperative specimen radiograph. The distribution of gender and race/ethnicity among the patients who underwent surgery reflects the community population and frequency of breast cancer development among men versus women. 45.1% of the cases involved malignancy, as determined pre-operatively. Positive margins requiring re-excision constituted 18.2% of cases. In twenty-six patients, two or three SmartClips™ were placed per case for either a bracketed lesion, two separate breast lesions, and/or a breast lesion and lymph node. Conclusion Although this study is limited in patient number, it demonstrates safety of this technique and its reliability in guiding the surgeon directly to the lesion(s) of concern.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3