A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig

Author:

Bünger Carsten Michael1,Grabow Niels2,Sternberg Katrin2,Goosmann Martin1,Schmitz Klaus-Peter2,Kreutzer Hans J.3,Ince Hüseyin4,Kische Stefan4,Nienaber Christoph A.4,Martin David P.5,Williams Simon F.5,Klar Ernst1,Schareck Wolfgang1

Affiliation:

1. Department of Surgery, University of Rostock, Germany

2. Department of Biomedical Engineering, University of Rostock, Germany

3. Department of Pathology, University of Rostock, Germany

4. Department of Cardiology and Institutes, University of Rostock, Germany

5. Tepha, Inc., Lexington, Massachusetts, USA

Abstract

Purpose: To assess the technical feasibility and biocompatibility of a novel stent based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for peripheral vascular applications. Methods: A polytetrafluoroethylene aortobi-iliac graft was implanted in 5 pigs through a midline abdominal incision. After transverse graft limb incision, 5 PLLA/P4HB stents and 5 metal stents (316L stainless steel) were randomly deployed at both iliac anastomotic sites with 6-mm balloon catheters. Angiography was performed to determine patency prior to sacrifice at 6 weeks. Stented segments were surgically explanted and processed for quantitative histomorphometry. Vascular injury and inflammation scores were assigned to the stented iliac segments. Results: No animals were lost during follow-up. All PLLA/P4HB stents were deployed within 2 minutes by balloon inflation to 8 bars without rupture of the stent struts or anastomotic suture. All stents were patent on postprocedural angiography. Histological analysis showed no signs of excessive recoiling or collapse. PLLA/P4HB stents demonstrated decreased residual lumen area and increased neointimal area after 6 weeks (12.27±0.62 and 8.40±1.03 mm2, respectively) compared to 316L stents (13.54±0.84 and 6.90±1.11 mm2, respectively) as the result of differences in stent areas (PLLA/P4HB: 4.31±0.15 mm2; 316L: 2.73±0.29 mm2). Vascular injury scores showed only mild vascular trauma for all stents (PLLA/P4HB: 0.41±0.59; 316L: 0.32±0.47). Inflammatory reaction was slightly higher around PLLA/P4HB stent struts (1.39±0.52) compared to 316L (1.09±0.50). Conclusion: Rapid balloon expansion of PLLA/P4HB stents is feasible without risk of strut rupture. PLLA/P4HB stents provide adequate mechanical stability after iliac anastomotic stenting in pigs. Smaller residual luminal areas in the PLLA/P4HB stents might have been caused by tissue ingrowth into the larger strut interspaces due to higher strut thickness (stent area) in this group. This limitation needs to be addressed in future work on the stent design.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献