Pivotal Study of a Next-Generation Balloon-Expandable Stent-Graft for Treatment of Iliac Occlusive Disease

Author:

Bismuth Jean1,Gray Bruce H.2,Holden Andrew3,Metzger Christopher4,Panneton Jean5,

Affiliation:

1. DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, TX, USA

2. University of South Carolina School of Medicine, Greenville, SC, USA

3. Auckland University School of Medicine, Auckland, New Zealand

4. Wellmont CVA Heart Institute, Kingsport, TN, USA

5. Eastern Virginia Medical School, Norfolk, VA, USA

Abstract

Purpose: To evaluate the safety and efficacy of a next-generation balloon-expandable stent-graft for the treatment of arterial occlusive disease in patients with de novo or restenotic lesions in the common and/or external iliac arteries. Methods: A prospective, multicenter, single-arm safety and efficacy study ( ClinicalTrials.gov identifier: NCT02080871) of the VBX Stent Graft for treatment of de novo or restenotic lesions in the iliac arteries was conducted under an Investigational Device Exemption at 26 US sites and 1 New Zealand center. The study eligibility criteria were established with the aim of enrolling more “real-world” patients compared with previous iliac stent studies supporting Food and Drug Administration approval. The study enrolled 134 patients (mean age 66±9.5 years; 79 men) with 213 iliac lesions. Three-quarters of the population (101, 75.4%) had Rutherford category 3 ischemia, and 43 (32.1%) patients presented with TASC II C/D lesions. The primary endpoint was a composite of device- or procedure-related death within 30 days, myocardial infarction within 30 days, target lesion revascularization (TLR) within 9 months, and amputation above the metatarsals in the treated leg within 9 months. Results: In all, 234 devices were implanted in 213 lesions with 100% technical success; 57 (42.5%) patients received kissing stents at the aortic bifurcation. No devices exhibited a discernable change in length after final deployment as determined by independent core laboratory quantitative angiographic analysis. At 9 months, 3 (2.3%) of 132 patients (1 lost to follow-up, 1 unrelated death) experienced a major adverse event (3 TLRs) related to the primary endpoint. At 9 months, there were no device-related serious adverse events or unanticipated adverse device effects. Conclusion: The next-generation balloon-expandable stent-graft demonstrated notable 9-month safety and efficacy in treating iliac occlusive disease in patients reflecting common clinical practice.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3