Changes in Target Vessel Anatomy Following Fenestrated Endovascular Aneurysm Repair: Midterm Results

Author:

Keschenau Paula R.1ORCID,Sattler Christina1,Berger Tanja2,Kotelis Drosos1,Jacobs Michael J.13,Kalder Johannes1ORCID

Affiliation:

1. Department of Vascular Surgery, European Vascular Center Aachen-Maastricht, RWTH University Hospital Aachen, Germany

2. Department of Medical Statistics, RWTH University Hospital Aachen, Germany

3. Department of Vascular Surgery, European Vascular Center Aachen-Maastricht, AZM University Hospital, Maastricht, the Netherlands

Abstract

Purpose: To analyze the changes in target vessel (TV) anatomy after fenestrated endovascular aneurysm repair (fEVAR) during midterm follow-up. Materials and Methods: A retrospective single-center study analyzed 56 patients (mean age 71±7 years; 49 men) who underwent fEVAR using custom-made stent-grafts (22 Zenith and 34 Anaconda) between June 2010 and July 2016. Advanta V12 (V12; 74, 53%) and BeGraft (BeG; 66, 47%) stent-grafts were used to bridge to the 140 TVs. Measurements of the TV deviation at the aortic origin, the vessel shift distal to the bridging stent-graft (BSG), and the outer and inner BSG curve lengths were performed after 3-dimensional reconstruction of the serial computed tomography angiography scans. The results of the measurements for the main devices, the TVs, and the bridging stent-grafts were compared using univariable and multivariable analysis. Results: Of the 140 BSGs examined (74 V12s and 66 BeGs), 393 measurements (38 celiac trunks, 102 superior mesenteric arteries, 121 left renal arteries, and 132 right renal arteries) were analyzed. The outer/inner BSG curve length ratio was larger after implantation of Zenith devices compared with Anaconda (p<0.001). The vessel shift distal to the BSG was significantly associated with the interaction of the TV and type of BSG only in the univariable analysis (p=0.001). There were no significant changes of the TV deviation at the aortic origin. Only the outer BSG curve length was significantly associated with TV complications (p=0.033). Median follow-up was 24 months (range 2–61). The BSG curve length ratio showed a significant increase over time (p<0.001) but did not differ between the BeG and V12 (p=0.381). Conclusion: No difference was found between the V12 and the BeG stent-grafts regarding anatomical TV changes during midterm follow-up after fEVAR. Both stent-grafts adapt to the TV anatomy over time, and moderate anatomical changes seem to be tolerated without increasing the risk for TV complications. The type of main device also influences the TV anatomy.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3