In-stent Restenosis After Stenting for Superior Mesenteric Artery Dissection Is Associated With Stent Landing Zone: From Clinical Prediction to Hemodynamic Mechanisms

Author:

Mei Junhao1,Yan Hui2,Zhao Xi3,Yuan Yuan4,Su Haobo4,Xue Tongqing5,Jia Zhongzhi1ORCID

Affiliation:

1. Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People’s Hospital, Nanjing Medical University, Changzhou, China

2. Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China

3. Central Research Institute, United Imaging Healthcare, Shanghai, China

4. Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, China

5. Department of Interventional Radiology, Huaian Hospital of Huai’an City, Huai’an, China

Abstract

Objective: To identify risk factors for in-stent restenosis (ISR) in patients undergoing stent placement for superior mesenteric artery dissection (SMAD) and to determine the hemodynamic mechanism underlying ISR. Methods: For this retrospective study, patients with SMAD who had ISR after stent placement were included in the ISR group, and age- and sex-matched patients with SMAD who did not experience ISR after stent placement were included in the control group. Clinical, imaging, and hemodynamic data were assessed. Multivariable regression was used to identify independent ISR risk factors. Structural and fluid dynamics simulations were applied to determine the hemodynamic mechanism underlying the occurrence of ISR. Results: The study population included 26 patients with ISR and 26 control patients. Multivariate analysis demonstrated that stent-to-vascular (S/V) ratio (odds ratio [OR], 1.14; 95% confidence interval [CI]: 1.00–1.29; p=0.045), stent proximal position >10 mm away from the SMA root (OR, 108.67; 95% CI: 3.09–3816.42; p=0.010), and high oscillatory shear index (OSI) area (OR, 1.25; 95% CI: 1.02–1.52; p=0.029) were predictors of ISR. In structural and fluid dynamics simulations, a stent proximal position near the abdominal aorta (AA) or entering into the AA reduced the contact area between the proximal struts of the stent and the vascular wall, and alleviated the distal lumen overdilation. Conclusion: The S/V ratio, stent proximal position away from the SMA root (>10 mm), and high OSI area are independent risk factors for ISR in patients with SMAD undergoing stent placement. Deploying the proximal end of the stent near the AA or entering into the AA appears to improve the hemodynamic environment in the SMA lumen and ultimately reduce the risk of ISR. Clinical Impact In-stent restenosis is an uncommon but potentially catastrophic complication after stent placement for the management of superior mesenteric artery dissection. This study identified risk factors for in-stent restenosis and demonstrated that, as long as the stent can fully cover the dissection range, deploying the proximal end of the stent near the abdominal aorta or less entering into the abdominal aorta may reduce the risk of in-stent restenosis in this patient population.

Funder

china postdoctoral science foundation

Research Project of Changzhou Medical Center of Nanjing Medical University

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3