Three-Dimensional Intravascular Ultrasound Assessment of Abdominal Aortic Aneurysm Necks

Author:

van Essen Jeroen A.,Gussenhoven Elma J.,Blankensteijn Jan D.1,Honkoop Jan,van Dijk Lukas C.2,van Sambeek Marc R.H.M.3,van der Lugt Aad2

Affiliation:

1. Department of Vascular Surgery, University Medical Center, Utrecht, The Netherlands

2. Department of Radiology, University Hospital Rotterdam-Dijkzigt and the Erasmus University, Rotterdam

3. Department of Vascular Surgery, University Hospital Rotterdam-Dijkzigt and the Erasmus University, Rotterdam

Abstract

Purpose: To document the accuracy of an automated analysis system for measuring lumen diameter and neck lengths of abdominal aortic aneurysms (AAAs) from intravascular ultrasound (IVUS) images and to describe additional features associated with 3-dimensional (3D) IVUS imaging. Methods: Twenty-two aortic aneurysms were studied with IVUS. Lumen diameters obtained using the automated analysis system were compared with manual measurements from axial IVUS scans, as were neck lengths obtained using automated analysis versus those measured with the aid of a displacement sensing device. Automated analyses were repeated by a second observer. Agreement was expressed as the coefficient of variation (CV). Results: Twenty proximal aortic, 6 distal aortic, and 3 iliac necks were available for analysis. Comparison between automated analysis and manual measurements for lumen diameter revealed a difference of 0.45 ± 0.42 mm (mean ± SD, Pearson's r = 0.99, p < 0.001, CV = 2.1%) and a difference of 0.05 ± 0.12 cm (r = 0.99, p = 0.04, CV = 4.1%) for neck length. Interobserver difference for lumen diameter was 0.13 ± 0.66 mm (r = 0.99, p < 0.001, CV = 3.4%) and 0.05 ± 0.11 cm for length measurements (r = 0.99, p = 0.02, CV = 3.5%). The 3D IVUS imaging facilitated the identification of neck configuration. Conclusions: Automated analysis of IVUS images allows accurate measurement of the lumen diameter of proximal and distal AAA necks and gives length measurements comparable to those of manual analysis. Longitudinal display of IVUS images aids in the elucidation of neck anatomy.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3