The Minimum Frequency of Glucose Measurements from Which Glycemic Variation Can Be Consistently Assessed

Author:

Baghurst Peter A.12,Rodbard David3,Cameron Fergus J.4

Affiliation:

1. Public Health Research Unit, Women's and Children's Hospital, Children Youth and Women's Health Service, North Adelaide, South Australia

2. Discipline of Paediatrics, Faculty of Health Sciences, University of Adelaide, Adelaide, South Australia

3. Biomedical Informatics Consultants LLC, Potomac, Maryland

4. Department of Endocrinology and Diabetes, Royal Children's Hospital, University of Melbourne, Murdoch Children's Research Institute Parkville, Melbourne, Victoria, Australia

Abstract

Aims: While there has been much debate about the clinical importance of glycemic variation (GV), little attention has been directed to the properties of data sets from which it is measured. The purpose of this study is to assess the minimum frequency of glucose measurements from which GV can be consistently and meaningfully measured. Methods: Forty-eight 72 h continuous glucose monitoring traces from children with type 1 diabetes were assessed. Measures of GV included standard deviation (SD), mean amplitude of glycemic excursion (MAGE), and continuous overlapping net glycemic action (CONGA1–4). Measures of GV calculated using 5 min sampling were designated as the 100% or “best estimate” value. Calculations were then repeated for each patient using glucose values spaced at increasing intervals. For each of the specified sampling frequencies, the ratio (%) of the between-subject SD based on the reduced subset of data to the estimate of the SD based on the full 5 min sampling data set was calculated. Results: As the interval between observations increased, so did the variability of the estimators of GV. Standard deviation exhibited the least systematic change at all measurement intervals, and MAGE exhibited the greatest systematic change. Conclusions: In patients with type 1 diabetes, GV as measured by SD or CONGA4, becomes unreliable if observations are more than 2–4 h apart, and estimates of MAGE become unreliable if glucose measurements are more than 1 h apart. MAGE is more unstable and prone to random measurement error than either SD or CONGA. The frequency of glycemic measurements is thus pivotal when selecting a parameter for measurement of GV.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3