Performance of Cleared Blood Glucose Monitors

Author:

Klonoff David C.1,Prahalad Priya2

Affiliation:

1. Diabetes Research Institute, Mills-Peninsula Health Services, San Mateo, CA, USA

2. Division of Pediatric Endocrinology, University of California, San Francisco, San Francisco, CA, USA

Abstract

Cleared blood glucose monitor (BGM) systems do not always perform as accurately for users as they did to become cleared. We performed a literature review of recent publications between 2010 and 2014 that present data about the frequency of inaccurate performance using ISO 15197 2003 and ISO 15197 2013 as target standards. We performed an additional literature review of publications that present data about the clinical and economic risks of inaccurate BGMs for making treatment decisions or calibrating continuous glucose monitors (CGMs). We found 11 publications describing performance of 98 unique BGM systems. 53 of these 98 (54%) systems met ISO 15197 2003 and 31 of the 98 (32%) tested systems met ISO 15197 2013 analytical accuracy standards in all studies in which they were evaluated. Of the tested systems, 33 were identified by us as FDA-cleared. Among these FDA-cleared BGM systems, 24 out of 32 (75%) met ISO 15197 2003 and 15 out of 31 (48.3%) met ISO 15197 2013 in all studies in which they were evaluated. Among the non-FDA-cleared BGM systems, 29 of 65 (45%) met ISO 15197 2003 and 15 out of 65 (23%) met ISO 15197 2013 in all studies in which they were evaluated. It is more likely that an FDA-cleared BGM system, compared to a non-FDA-cleared BGM system, will perform according to ISO 15197 2003 (χ2 = 6.2, df = 3, P = 0.04) and ISO 15197 2013 (χ2 = 11.4, df = 3, P = 0.003). We identified 7 articles about clinical risks and 3 articles about economic risks of inaccurate BGMs. We conclude that a significant proportion of cleared BGMs do not perform at the level for which they were cleared or according to international standards of accuracy. Such poor performance leads to adverse clinical and economic consequences.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Analyse accuracy of glucose monitors without any dedicated software package;Indian Journal of Endocrinology and Metabolism;2022

2. Automated Adaptation of Insulin Treatment in Type 1 Diabetes;2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC);2021-11-01

3. Post-Market Surveillance Assessment of the Clinical Accuracy of a Blood Glucose Monitoring System with an Improved Algorithm for Enhanced Product Performance;Journal of Diabetes Science and Technology;2021-08-31

4. Choosing a Mobile Sensor Technology for a Clinical Trial: Statistical Considerations, Developments and Learnings;Therapeutic Innovation & Regulatory Science;2020-06-18

5. The closed‐loop artificial pancreas in 2020;Artificial Organs;2020-05-08