Theoretical and practical considerations for crosswell electromagnetic tomography assuming a cylindrical geometry

Author:

Alumbaugh David L.1,Morrison H. Frank2

Affiliation:

1. Engineering Geoscience, University of California at Berkeley and Lawrence Berkeley Laboratory

2. Department of Mineral Engineering, 577 Evans Hall, University of California at Berkeley, Berkeley, CA 94720

Abstract

An iterative Born imaging scheme is employed to analyze the resolution properties of crosswell electromagnetic tomography. The imaging scheme assumes a cylindrical symmetry about a vertical magnetic dipole source and employs approximate forward modeling at each iteration to update the internal electric fields. Estimation of the anomalous conductivity is accomplished through least‐squares inversion. Much of the mathematical formulation of this diffusion process appears similar to the analysis of wavefield solutions, but the attenuation implicit in the complex propagation constant invalidates many of the accepted wavefield criteria for resolution. Images of illustrative models show that vertical resolution improves with increasing frequency and with increased spatial sampling density. In addition, greater conductivity contrasts between the target and the background can result in better resolution. The horizontal resolution depends on the maximum aperture that is employed and with increasing frequency, larger apertures are needed to obtain optimal results. However, the maximum aperture that can be employed, and thus the horizontal resolution, is limited by the rate of attenuation and the noise present in the measurements. Weighting the long‐offset data equally with the zero‐offset data can improve the resolution if the noise is not a function of the dynamic range of the measurement system. At lower frequencies, the resolution can be improved by measuring both the horizontal and vertical components of the magnetic fields. In addition, multiple frequencies can be employed to improve the resolution for limited aperture measurements. The general applicability of the cylindrically symmetric geometry is examined by comparing the 2-D sensitivity functions to those produced by a 2.5-D model, and by imaging a 3-D body with the 2-D iterative Born scheme. For borehole separations greater than five skin depths it is demonstrated that the measurements, and thus the images, are not affected by the geometry of the conductive zone outside of the interwell plane. Thus the 2-D imaging scheme can be employed in these situations. For borehole separations less than five skin depths, artifacts are produced in the images which will lead to faulty interpretations.

Publisher

Society of Exploration Geophysicists

Subject

Geochemistry and Petrology,Geophysics

Cited by 60 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Signal processing methods for crosswell electromagnetic imaging system;Interpretation;2023-02-01

2. EM Receiving Techniques of Cross-Well EM Imaging Well Logging System Research and Development;Springer Series in Geomechanics and Geoengineering;2023

3. Long-Distance Crosswell EM Logging of Copper Ore Using Borehole-Surface Current Injection in Slim Holes;IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing;2022

4. An Inversion Method for Cross Well Electromagnetic Imaging through Casing;2021 13th International Symposium on Antennas, Propagation and EM Theory (ISAPE);2021-12-01

5. A Compact Microwave Imager Integrated With a Miniaturized Dual-Angle Anechoic Chamber;IEEE Transactions on Microwave Theory and Techniques;2021-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3